Description
3.2 Derating factors
The following components and settings influence the noise levels reached when built-in motors
are operational:
• Machine design
• Encoder system
• Bearing
• Controller settings
• Pulse frequency
As a result of unfavorable machine designs, configuration or system settings, measuring
surface sound pressure levels of over 70dB (A) can occur. You can obtain support on
the topics of "Application" and "Mechatronics" at Application & Mechatronic Support Direct
Motors
3.2

Derating factors

For installation altitudes above 2000 m above sea level, reduce the voltage stress of the motors
according to table "Factors to reduce the maximum DC link voltage" (reciprocal values from EN
60664‑1 Table A. 2).
Table 3-3
Installation altitude above sea level in m up to
Reducing the DC link voltage reduces the converter output voltage. The operating range in
the F‑v diagram is thus also reduced.
You can find the F‑v diagrams in the associated data sheet.
Operation in a vacuum is not permissible due to the low voltage strength and the poor
cooling.
38
(mailto:
motor.support.motioncontrol@siemens.com).
Factors to reduce the maximum DC link voltage
2000
3000
4000
5000
6000
7000
8000
Factor
1
0.877
0.775
0.656
0.588
0.513
0.444
Naturally-Cooled 1FN3 Linear Motors
Operating Instructions, 06/2023, A5E52220465B AB