Environmental Conditions - Siemens SIMOTICS S-1FK7 DYA Generation 2 Operating Instructions Manual

Synchronous motors with planetary gearbox
Table of Contents

Advertisement

Description of the motors
2.2 Technical features and environmental conditions
2.2.3

Environmental conditions

You can classify the environmental conditions according to standard DIN EN 60721-3-3 for
fixed installation locations that are weather protected. The environmental effects and their
limit values are defined in various classes in this standard.
With the exception of environmental influences "Condensation", "Low air temperature" and
"Low air pressure", you can assign SIMOTICS S servomotors to climate class 3K4.
The following temperature ranges apply for natural-cooled and forced-ventilation motors.
Table 2- 3
Influencing environmental variables
a)
b)
c)
d)
e)
f)
g)
h)
i)
j)
k)
l)
m)
n)
o)
p)
1)
2)
3)
4)
Note
Installation instructions
SIMOTICS S motors are not suitable for operation
• In salt-laden or aggressive atmospheres
• Outdoors
26
Environmental conditions are based on climate class 3K4
Low air temperature
High air temperature
Low relative humidity
High relative humidity
Low absolute humidity
High absolute humidity
Rate of temperature change
Low air pressure
4)
High air pressure
2)
Solar radiation
Thermal radiation
Air movement
3)
Condensation
Wind-driven precipitation
(rain, snow, hail, etc.)
Water (other than rain)
Formation of ice
Averaged over a period of 5 min
Conditions in mines are not considered.
A cooling system based on natural convection can be disturbed by unforeseen air movements.
The limit value of 89 kPa covers applications at altitudes up to 1000 m.
1)
S-1FK7 DYA G2 synchronous motors with planetary gearbox
Operating Instructions, 05/2018, A5E44881183B AA
Unit
Value
°C
- 15
°C
+ 40
%
5
%
95
g/m
1
3
g/m
29
3
°C/min
0.5
kPa
89
kPa
106
W/m
700
2
-
-
m/s
1.0
-
Not permissible
-
-
-
See protection
class
-
-

Advertisement

Table of Contents
loading