Siemens SIMOTICS S-1FK7 DYA Generation 2 Operating Instructions Manual page 65

Synchronous motors with planetary gearbox
Table of Contents

Advertisement

Connection scheme for the motor to the S120 Power Module and Motor Module Booksize
and Compact with a MOTION CONNECT cable
For connector size 1
1
2
3
4
5
6
7
● Connect the shield at both ends at the motor and at the converter.
● Keep unshielded cable ends as short as possible.
● Establish the shield connection through a large surface area so that high-frequency
currents are suitably discharged. Establish a 360° connection at the converter and at the
motor, for instance using EMC cable glands at the cable entries.
S-1FK7 DYA G2 synchronous motors with planetary gearbox
Operating Instructions, 05/2018, A5E44881183B AA
Connector, size 1
SPEED CONNECT connector, size 1
Terminal for the cable shield
Pin assignment
Circuit diagram
Cable shield
Conductor designation:
U, V, W = power cables, 1.5 mm
BD1+ and BD2- = brake cable without lettering, 1.5 mm
PE = protective conductor
, each cable separately shielded
2
, shared shield
2
Connecting