Siemens SIMOTICS S-1FK7 DYA Generation 2 Operating Instructions Manual page 39

Synchronous motors with planetary gearbox
Table of Contents

Advertisement

1FK703 to 1FK704: up to 2 ∙ I
1FK706: up to 4 ∙ I
NOTICE
Destruction of the motor for a thermally critical load
For load applications that are critical from a thermal perspective, e.g. overload when the
motor is stationary or an overload of M
available.
• Activate the "Thermal motor model i
The temperature sensor is part of a SELV circuit, which can be destroyed if high voltage is
applied. The temperature sensor is designed so that the DIN/EN requirement for "protective
separation" is complied with.
High short-term overload conditions require additional protective measures as a result of the
thermal coupling time of the temperature sensor.
NOTICE
Destruction of the motor for a thermal critical load
A thermally critical load, e.g. high overload when the motor is stationary, can destroy the
motor.
• Employ additional protective measures, e.g. an overcurrent relay.
S-1FK7 DYA G2 synchronous motors with planetary gearbox
Operating Instructions, 05/2018, A5E44881183B AA
and speed ≠ 0
0 (60 K)
and speed ≠ 0
0 (60 K)
max
t monitoring" function in the converter.
2
3.3 Thermal motor protection
longer than 4 s, adequate protection is no longer
Mounting and options
37

Advertisement

Table of Contents
loading