Description
3.3 Installation
Basic type of construc‐
tion code
IM B35 (IM 2001)
IM B34 (IM 2101)
3.3.7

Degree of protection

The machine has a type of protection as stamped on the rating plate, and can be installed in
dusty or humid environments.
3.3.8

Environmental conditions

Limit values for the standard version
Relative humidity for ambient temperature T
40 °C
Ambient temperature
Installation altitude
Air with normal oxygen content, usually
The standard machines are not suitable for use in corrosive atmospheres, atmospheres with a
high salt content, or outdoor applications.
Limit values for the special versions
If the environmental conditions are different from the details listed here, then the values on the
rating plate or in the catalog will apply.
3.3.9

Optional built-on and built-in accessories

Machines can be equipped with the following integrated components/devices:
• Temperature sensors integrated in the stator winding in order to monitor the temperature
and protect the stator winding from overheating.
• Anti-condensation heating for machines whose windings are subject to a risk of
condensation due to the climatic conditions.
Machines can be equipped with the following mounted components/devices:
• Brake
• Rotary pulse encoder
• External fan (forced ventilation)
26
Diagram
amb
Max. 55 %
-20 °C to +40 °C
≤ 1000 m
21 % (V/V)
1FZ shaft height 280
Operating Instructions, 02/2022, A5E51698698A