Transducer Cable Removal And Installation; Figure 3-15 Flow Meter Transducer Cables And Ports - Emerson Daniel 3814 Maintenance And Troubleshooting Manual

Liquid ultrasonic flow meter
Hide thumbs Also See for Daniel 3814:
Table of Contents

Advertisement

Maintenance and Troubleshooting Manual
3-9000-764 Rev F
3.4

Transducer cable removal and installation

Daniel 3810 Series Ultrasonic Flow Meters have blue transducer cables and a transducer cable
nut that threads directly into the back of the transducer housing. The cables use plastic glands
that come with the meter.

Figure 3-15 Flow meter transducer cables and ports

A. Base enclosure transducer cable glands
B. Cable ties (two locations)
C. 3814 Ultrasonic Meter transducer port and locking ring
D. Transducer mount and transducer cable
FLUID CONTENTS MAY BE UNDER PRESSURE
DO NOT remove the transducer locking ring while the line is pressurized.
Failure to do so may cause serious injury or equipment damage.
Transducer cable removal and installation
Section 3: Meter maintenance
December 2017
A.
B.
C.
D.
27