Max. cross section to control cables, cable with enclosed core .................................................. 0.5 mm
When complying with EN 55011 1A and EN 55011 1B the motor cable must be reduced in certain instances.
Control characteristics:
Frequency range ............................................................................................................ 0.2 - 132 Hz, 1 - 1000 Hz
Resolution of output frequency ......................................................................................... 0.013 Hz, 0.2 - 1000 Hz
Repeat accuracy of Precise start/stop (terminals 18, 19) .................................................................... ≤ ± 0.5 msec
System response time (terminals 18, 19, 27, 29, 33) .......................................................................... ≤ 26.6 msec
Speed control range (open loop) .................................................................................. 1:15 of synchronous speed
Speed control range (closed loop) .............................................................................. 1:120 of synchronous speed
Speed accuracy (open loop) ....................................................................... 90 - 3600 rpm: Max. error of ±23 rpm
Speed accuracy (closed loop) .................................................................... 30 - 3600 rpm: Max. error of ±7.5 rpm
All control characteristics are based on a 4-pole asynchronous motor
Surroundings:
Enclosure ....................................................................................................................................................... IP 20
Enclosure with options ............................................................................................................................... NEMA 1
Vibration test ............................................................................................................................................ 0.037 oz
Max. relative humidity .................................................................................................. 5% - 93% during operation
Ambient temperature .................................................. Max. 122 °F (45 °C) (24-hour average max. 113 °F (40 °C))
Derating for ambient temperature, see special conditions in the Design Guide
Min. ambient temperature during full-scale operation ..........................................................................
Min. ambient temperature at reduced performance ......................................................................... 14 °F (-10 °C)
Temperature during storage/transport ............................................................ -13 - +150/160 °F (-25 - +65/70 °C)
Max. altitude above sea level ........................................................................................................ 3280 ft (1000 m)
Derating for air pressure, see special conditions in the Design Guide
EMC standards, Emission ............................................................................. EN 50081-2, EN 61800-3, EN 55011
EMC standards, Immunity .................................................................................................................................. EN
50082-1/2, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61800-3
See section on special conditions in the Design Guide
Safeguards:
Electronic thermal motor protection against overload.
Temperature monitoring of the power module ensures that the adjustable frequency drive cuts
out if the temperature reaches 212 °F (100 °C). An overload temperature cannot be reset until
the temperature of the power module is below 160 °F (70 °C).
The frequency converter is protected against short-circuits on motor terminals U, V, W.
If an electrical phase is missing, the variable frequency drive will cut out.
Monitoring of the intermediate circuit voltage ensures that the variable frequency drive cuts out
if the intermediate circuit voltage is too low or too high.
The variable frequency drive is protected against ground fault on motor terminals U, V, W.