setups from one variable frequency drive to another
by moving the LCP 2 control panel.
Description of choice:
Select Upload all parameters [1] if you want all
parameter values to be transferred to the control panel.
Select Download all parameters [2] if all parameter
values transferred are to be copied to the frequency
converter to which the control panel is attached. Select
Download size-independent par. [3] if you only want
to downloade the size-independent parameters. This
is used when downloading to a variable frequency
drive with a different rated power size than that from
which the parameter setup originates.
NOTE
Upload/download can only be performed
in stop mode. Download can only be
performed to a frequency converter with
the same software version number, see parameter
626 Database identification no.
008 Display scaling of output frequency
(FREQUENCY SCALE)
Value:
0.01 - 100.00
Function:
In this parameter, the factor is selected by which the
output frequency is to be multiplied. The value is shown
in the display, provided parameters 009-012 Display
readout have been set to Output frequency x scaling [5].
Description of choice:
Set the required scaling factor.
009 Large display readout
(DISPLAY LINE 2)
Value:
No readout (NONE)
Resulting reference [%]
(REFERENCE %)
Resulting reference [unit]
(REFERENCE [UNIT])
Feedback [unit] (FEEDBACK [UNIT])
Frequency [Hz] (FREQUENCY [HZ])
Output frequency x scaling
(FREQUENCY X SCALE)
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.28.A8.22 - VLT is a registered Danfoss trademark
VLT® 2800 Series
Motor current [A] (MOTOR CURRENT [A])
Torque [%] (TORQUE [%])
Power[kW] (POWER[KW])
Power [HP] (POWER [HP][US])
Motor voltage [V]
(MOTOR VOLTAGE [V])
DC link voltage [V]
(DC LINK VOLTAGE [V])
Thermal load motor [%]
(MOTOR THERMAL [%])
Thermal load [%]
(FC. THERMAL[%])
Running hours [Hours]
(RUNNING HOURS])
Digital input [Bin]
(DIGITAL INPUT[BIN])
analog input 53 [V]
(ANALOG INPUT 53 [V])
Analog input 60 [mA]
(ANALOG INPUT 60 [MA])
Pulse reference [Hz]
(PULSE REF. [HZ])
External reference [%]
(EXTERNAL REF. [%])
Status word [Hex] (STATUS WORD [HEX])
Heatsink temperature [°C]
1.00
(HEATSINK TEMP [°C])
Alarm word [Hex] (ALARM WORD [HEX])
Control word [Hex] (CONTROL WORD [HEX])
Warning word [Hex]
(WARNING WORD [HEX])
Extended status word [Hex]
(EXT. STATUS [HEX])
Communication option card warning
(COMM OPT WARN [HEX])
Pulse count
(PULSE COUNTER)
Function:
In this parameter you can select the data value that
you wish to display in the LCP control unit display
[0]
line 2 when the variable frequency drive is switched
on. The display will also be included in the scrollbar
[1]
in display mode. In parameters 010-012 Display
readout you can select a further three data values,
[2]
which are displayed in display line 1.
[3]
Description of choice:
[4]
No readout can only be selected in parameters
010-012 Small display readout.
[5]
[6]
[7]
[8]
[9]
[11]
[12]
[13]
[14]
[15]
[16]
[17]
[19]
[20]
[21]
[22]
[25]
[26]
[27]
[28]
[29]
[30]
[31]
33