Connecting The Transducer Cable To The Transceiver - Simrad ES38-18/200-18CR Installation Manual

Table of Contents

Advertisement

Related topics
Connecting ES38-18/200-18CR transducer to a 12-pin Amphenol socket, page 37
12-pin Amphenol plug, page 39
Connecting the transducer to the other transceivers, page 40
Connecting the transducer cable to the
transceiver
Once the transducer cable has been installed, you can connect it to the transceiver using
the plug provided.
Prerequisites
Electrical connections can only be made by skilled personnel (ship electricians,
technicians or engineers). All necessary tools and instruments required must be
available. The installation shipyard must prepare detailed drawings of the electrical
system, and identify each cable.
You must be equipped with a standard set of tools. This tool set must comprise the
normal tools for electronic and electromechanical tasks. This includes different
screwdriver types, pliers, spanners, a cable stripper, a soldering iron etc. Each tool
must be provided in various sizes. We recommend that all tools are demagnetized to
protect your equipment.
Context
The ES38-18/200-18CR transducer can be used with a variety of echo sounder
transceivers. These use different plugs and connectors. For specific information about
the transducer connection consult the relevant echo sounder manual.
Procedure
1
Make sure that an ample length of the transducer cable is available for maintenance
and replacement.
2
Cut the transducer cable.
3
Remove the insulation on the wires in the transducer cable.
4
Mount the transducer plug - or make the connection to the transceiver - as described
in the relevant echo sounder installation manual.
Related topics
12-pin Amphenol plug, page 39
Connecting the transducer to the other transceivers, page 40
436200/A
Installing the transducer
33