F
P
UNCTION
ROTOTYPE
ViStatus vtex1629_get_scanlist (ViSession vi, ViInt32 _VI_FAR channels[],ViPInt32 numberOfChannels);
F
P
UNCTION
ARAMETERS
vi = contains a session handle to the instrument. This handle is obtained by the function and remains valid until the
session is closed.
channels = an integer return array indicating which channels are included in the scan list. Valid return values: 0 to
47.
numberOfChannels = a return integer value indicating the number of channels currently included in the scan list.
Valid return values: 1 to 48.
D
I
R
V
ATA
TEM
ESET
ALUE
Not applicable to this function.
D
ESCRIPTION
This function queries and returns a list of channels currently configured to be sampled in the data acquisition
process. The channels array must be at least 48 elements long.
E
XAMPLE
ViSession instrumentHandle;
ViStatus status;
ViInt32 channels[VTEX1629_MAX_SCANLIST_LENGTH];
ViInt32 numberOfChannels;
...
status = vtex1629_get_scanlist(instrumentHandle, channels, &numberOfChannels);
EX1629 Command Set
vtex1629_get_scanlist
www.vtiinstruments.com
181