Intermec CK70 User Manual page 138

Hide thumbs Also See for CK70:
Table of Contents

Advertisement

Appendix A — Specifications and Default Settings
Symbology
Density
Code 39
0.25 mm (10 mils)
0.5 mm (20 mils)
1 mm (40 mils)
1.4 mm (55 mils)
2.5 mm (100 mils)
Code 128
2.5 mm (100 mils)
retro-reflective
126
EX25C Near-Far Range Imager Typical Reading
Distance
Typical reading distances are measured in an office environment (200
lux). The following graphics do not include the 0.24 cm (0.09 in)
setback for the CK71.
EX25C Near-Far Range Imager 1D Typical Reading Distances
80"
0"
40"
in
160"
128"
100% EAN
contrast UPC
96"
64"
32"
0"
32"
0.25 mm
10 mils
64"
0.5 mm/20 mils
1 mm/40 mils
96"
128"
160"
200
0
100
EX25C 1D Symbologies Typical Reading Distances With 0.24 cm (0.09
in) Setback
120"
160"
200"
240"
280"
2.5 mm/100 mils
300
400
500
600
700
Minimum Distance
15 cm (5.91 in)
16 cm (6.30 in)
25 cm (9.84 in)
40 cm (15.75 in)
**
**
70 Series Mobile Computer User's Manual
320"
360"
400"
440"
800
900
1000
1100
1200
Maximum Distance
135 cm (53.15 in)
280 cm (110.24 in)
550 cm (216.54 in)
720 cm (283.46 in)
1200 cm (472.44 in)
1300 cm (511.81 in)
480"
400
320
240
160
80
0
80
160
240
320
400
cm

Advertisement

Table of Contents
loading

This manual is also suitable for:

70 seriesCk71Cn70Cn70e

Table of Contents