Power Line Operation; Operating Temperature; Operators Adjustments And Basic Displays; Operators Adjustments - Tektronix 213 DMM Instruction Manual

Oscilloscope with options
Table of Contents

Advertisement

humidity, the batteries should be charged for at least 16
hours every two weeks, or leave the 213 connected
to
the
power line.
Charging
Temperature
0°C
+20
to +30°C
+40°C
TABLE 2-1
Battery Charge Capacity
Operating Temperature
-15°C
+20 to +30°C
40%
60%
65%
100%
40%
65%
+55°C
50%
85%
55%
Power Line Operation
This instrument can be operated from a power line voltage
of 90 to 136 V ac, 48 to 62 Hz.
In Option 1, it can be
operated from 180 to 250 V ac (48 to 62 Hz) or 180 to
250 V de.
Operating Temperature
The 213 can be battery operated in ambient air tempera-
tures between -15 and +55°C (+5 and +131°F). It should
be connected to the power line only in ambient air tempera-
tures between O and +40°C (+32 and +104°F).
OPERATORS ADJUSTMENTS
AND BASIC DISPLAYS
This section provides instructions for
making initial
opera-
tors adjustments and obtaining commonly used basic
dis-
plays. Since these procedures involve most of
the
controls
and connectors,
they
can be
used for basic familiarization
on the operation of
the instrument.
Before starting
the
checkout, either
charge
the batteries for at
least
16 hours
or
connect the instrument to the power
line.
@
I
WARNING
I
When battery operated, store the power line
plug in the rear panel insulated compartment.
Potentials applied to the common connectors
may cause small amounts of current to flow in
the power line circuitry creating a possible shock
hazard on the power plug prongs.
Operating lnstructions-213 Service
I
_
WARNING
I
The probe common clip and the COMMON jack
are electrically connected to each other, and
potentials applied to one are present on
the
other,
creating a possible shock hazard.
~
The probe common clip and the COMMON jack
are electrically connected to each other and dis-
similar voltages applied to the common clip and
COMMON jack can cause equipment damage.
Operators Adjustments
The equipment required to make the initial operators ad-
justments is a screwdriver with a minimum blade size of
3/32 inch. To obtain the basic displays, a de source, an ac
source, and one or two resistors are required. Suggested
items for the basic displays are a battery, an audio signal
generator, a 3 kn resistor, and a 100 kn
resistor-
.
1. Set the controls as follows:
POWER
ON
GND
AUTO
INPUT COUPLING
TRIGGER
LEVEL-SLOPE
Midrange of either slope (do
not set at control midrange)
VOLTS-mA/DIV
CAL detent
VAR
HORIZ
MGF VAR
CAL detent
POS (both)
Midrange of control
DMM (OUT:SCOPE)
Button
out
RMS
(OUT:DC)
Button
out
Button in
1 (blue scale)
.5
m
VOLTS
VOLTS-mA/DIV
SEC/DIV
INTENSITY
Minimum for a visible trace
2. Set the SEC/0 IV control to .5 and adjust the FOCUS
control (screwdriver adjustment on
the
side panel) for the
2-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents