Typical High Voltage Multiplier Voltages
Measurement Location
Test Point
Typical Voltage (Vdc)
Across C506
12
190
Across C511
13
185
Across C513
14
185
Across C515
15
185
Across C523
16
175
From junction of C515 & C519 to junction
17
180
of C517 and C521
From junction of C517 & C521 to junction
18
180
of C519 and CR519/CR520
From junction of C519 and CR519/CR520
19
170
to junction of C521 and C523
@