213 Service
MORE-q
SPECIAL CONDITIONS
Special conditions are established after all controls are set as specified in 213 CONTROL SETTINGS on the
VOLTAGE AND WAVEFORM CONDITIONS pullout page.
( 1) D MM mode of operation.
(2) Oscilloscope mode of operation.
(3) Set VOLTS-mA/DIV to 100 krl;
n
button in; connect a 100 krl, 0.1% resistor for measurement.
(4) For voltages at test points
Input
Test
Coupling
Point
Ground
17
-0.55
18
+6.4 V
19
+0.55
,.
20
ov
0,00
&
@ ,
see Table 9-1.
TABLE 9-1
Overrange Voltages
+5
V INPUT
Input Coupling= DC
VOL TS-mA/DIV Range
10 (Blue)
1 (Blue)
(Normal)
(Overranged)
ov
+4.2
+6.4 V
+6.4
V
+1 V
+4.5
V
ov
0.7 V
-5
V INPUT
Input Coupling= DC
VOLTS-mA/DIV Range
10 (Blue)
1 (Blue)
(Normal)
(Overranged)
-1V
-5.3
+6.4
V
+5.7
V
ov
-4.2
V
0
0.7 V
(5) Input
is
a positive 4 V peak pulse at 1 kHz with a duty cycle of 20%; INPUT COUPLING is AC. Pattern
is centered vertically on 213.