Other Features - Carrier CDF-20Q7 Owner's Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
within 8 minutes, the unit will exit Wireless connection mode
automatically and the Wireless indicator illuminates and the
unit enters the previous functions. If connection is failure
within 8 minutes, the unit exits the Wireless connection mode
automatically.
Display
8
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
(±5% accuracy) room % humidity level in a range of

Other features

Bucket Full Light
Glows when the bucket is ready to be emptied, or when the
bucket is removed or not replaced in the proper position.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or when
the bucket is removed or not replaced in the proper position.
For some models the fan motor will continue operating for 30
seconds.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will
cycle off and the fan will continue to run until the frost disappears.
NOTE: When Auto defrosting operation, the unit may make a
voice of refrigerant flowing, it is normal.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart opertation in
the first 3 minutes. This is to protect the unit. Operation will
automatically start after 3 minutes.
CONTROL PADS ON THE DEHUMIDIFIER
30%RH (Relative Humidity) to 90%RH (Relative Humidity).
Error Codes and Protection Codes:
AS- Humidity sensor module error-Unplug the unit and plug it
back in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position-- Empty the
bucket and replace it in the right position.
Smart dehumidifying mode(optional)
At smart dehumidifying mode, the unit will automatically control
room humidity in a comfortable range 45%~55% according to the
room temperature. The humidity setting function will be invalid.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut, it will
restart with the previous function setting automatically when the
power resumes.
Setting the Timer
● Press to initiate the Auto start or Auto stop feature, in
conjuction with the
● When the unit is on, press the Timer pad to actieve the
AUTO STOP featrue. When the unit is off, press this button
to actieve the AUTO START feature.
● Press or hold the UP or DOWN pad to change the Auto
time by 0.5 hour increments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control will countdown the
time remaining until start.
13
and
pads.