CONTROL PADS ON THE DEHUMIDIFIER

NOTE: The control panel of the unit you purchased may be slightly different according to the
models.
ON
Ion
Fan
Timer
OFF
7
6
5

Control pads

When you push the pad to change
operation modes, the unit will make
a beep sound to indicate that it is
changing modes and the corresponding
indicators in Display Window illuminate.
1
Power Pad
Press to turn the dehumidifier on and off.
Mode Pad
2
Press to select the desired operation mode from
Dehumidifying,Dryer,Continuous dehumidifying and
Smart dehumidifying.
NOTE: Dryer and Smart dehumidifying modes are
optional.
3
4
: Down/Up Pads
Humidity Set Control Pads
The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the
pad and set to a lower
percent value(%).
For damper air, press the
pad and set a higher
percent value(%).
TIMER Set Control Pads
Use the Up/Down pads to set the Auto start and
Auto stop time from 0.0 to 24.
Timer Pad
5
Press to initiate the Auto start and Auto stop feature,
in conjuction with the
and
key pads.
Fan Pad
6
Control the fan speed. Press to select either High
or Normal fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.
8
3
Mode
ON
OFF
4
2
Ion Pad(optional)
7
Press to activate the ionizer. Anions ar automatically
generated by ionization. The anions deactive the
airborne chemical vapors and dust particles. Press
it again to stop the function.
NOTE:When the Display Window is dark,
first press any Pads (except the Power
Pad) to make the Display Window light,
press again to set desired operation
modes.
8
Display Window
Shows the set % humidity level from 35% to 85% or
auto start/stop time (0~24) while setting, then shows
the actual( ± 5% accuracy) room % humidity level
in a range of 30%RH(Relative Humidity) to 90%RH
(Relative Humidity).
Error Codes and Protection Codes:
AS- Humidity sensor error--Unplug the unit and plug it
back in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit and
plug it back in. If error repeats, call for service.
P1- Unit is defrosting-- Allow the unit time to automati-
cally defrost. The protection will clear after the unit self
defrosts.
P2- Bucket is full or bucket is not in right position--
Empty the bucket and replace it in the right position.
E3- Unit malfunction-- Unplug the unit and plug it back
in. If error repeats, call for service.
Indicators on Display Window:
-Displays when the Filter operation is on (unavilable
on this unit).
-displays when Bucket is full.
-Displays when Normal Fan function is set.
-Displays when High Fan function is set.
4
-Displays when Ion function is set.
-Displays when Timer ON function is set.
ON
-Displays when Timer OFF function is set.
OFF
-Displays when Dehumidifying mode is set.
Power

Other features

Bucket Full indicator
Glows when the bucket is ready to be
1
emptied, or when the bucket is removed
Fig.1
or not replaced in the proper position.
Auto Shut Off
The
dehumidifier
shuts off when the bucket is full,
or when the bucket is removed or not replaced in
the proper position.When the setting humidity is
reached, the unit will be shut off automatically.
For some models,the fan motor will continue
operating.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
NOTE:When Auto defrosting operation,the unit may
make a voice of refrigerant flowing,it is normal.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
Smart dehumidifying mode(optional)
At smart dehumidifying mode, the unit will automatically
control room humidity in a comfortable range 45%~55%
according to the room temperature. The humidity setting
function will be invalid.
CONTROL PADS ON THE DEHUMIDIFIER
-Displays when Dryer mode is set.
-Displays when Continuous Dehumidifying mode is set.
-Displays when Smart Dehumidifying mode is set.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.
Setting the Timer
When the unit is on, first press the Timer
button, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
When the unit is off, first press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again the
Time Off indecator light illuminates.It
indicates the Auto Stop is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights illuminate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.