Other Features - Carrier CDP-30Q7 Owner's Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
For damper air, press the ► pad and set a higher percent
value (%).
• TIMER Set Control Pads
Use the Up/Down pads to set the Auto start and Auto stop
time from 0.0 to 24.
Power Pad
8
Press to turn the dehumidifier on and off.
Display
9
Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual (±
5% accuracy) room % humidity level in a range of 30% RH
(Relative Humidity) to 90%RH (Relative Humidity).
Error Codes and Protection Code:

Other features

Bucket Full Light
Glows when the bucket is ready to be emptied.
Auto Shut Off
The dehumidifier shuts off when the bucket is full, or when
the bucket is removed or not replaced in the proper position.
For some models the fan motor will continue operating for 30
seconds.
Auto Defrost
When frost builds up on the evaporator coils, the compressor will
cycle off and the fan will continue to run until the frost disappears.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart opertation in
the first 3 minutes. This is to protect the unit. Operation will
automatically start after 3 minutes.
Check filter feature
The system starts to count the time once the fan motor operates.
The check filter feature can be only activated when the
accumulated operation time achieves 250 hours or more. The
Reset light (Clean filter indicator light) flashes at one time per
second, after finishing clean the air filter, press the Filter pad and
the Reset light (Clean filter indicator light) goes off.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut, it will
restart with the previous function setting automatically when the
CONTROL PADS ON THE DEHUMIDIFIER
AS- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES- Tube Temperature sensor of the evaporator error--
Unplug the unit and plug it back in. If error repeats, call for
service.
P2- Bucket is full or bucket is not in right position-- Empty the
bucket and replace it in the right position. (only available for
the unit with no pump feature.)
P2- Bucket is full -- Empty the bucket. (only available for the
unit with pump feature.)
Eb- Bucket is removed or not in right position-- Replace the
bucket in the right position. (only available for the unit with
pump feature.)
power resumes.
Setting the Timer
● When the unit is on, first press the Timer button, the Timer
Off indicator light illuminates. It indicates the Auto Stop
program is initiated. Press it again the Time On indecator
light illuminates. It indicates the Auto Start is initiated.
● When the unit is off, first press the Timer button, the TIMER
ON indicator light illuminates. It indicates the Auto Start
program is initiated. Press it again the Time Off indecator
light illuminates. It indicates the Auto Stop is initiated.
● Press or hold the UP or DOWN pad to change the Auto
time by 0.5 hour increments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control will count down the
time remaining until start.
● The selected time will register in 5 seconds and the system
will automatically revert back to display the previous humidity
setting.
● When the Auto start & Auto stop times are set, within the
same program sequence, TIMER ON OFF indicator lights
illuminate identifying both ON and OFF times are now
programmed.
● Turning the unit ON or OFF at any time or adjusting the timer
setting to 0.0 will cancel the Auto Start/Stop function.
● When LED display window displays the code of P2, the Auto
Start/Stop function will also be cancelled.
13