Keithley System SourceMeter 2601B Instrument Specifications page 8

Hide thumbs Also See for System SourceMeter 2601B:
Table of Contents

Advertisement

Models 2601B, 2602B and 2604B System SourceMeter
MEASUREMENT SPEED CHARACTERISTICS
Maximum sweep operation rates (operations per second) for 60 Hz (50 Hz):
A/D
Trigger
converter
origin
speed
0.001 NPLC
Internal
0.001 NPLC
Digital I/O
0.01 NPLC
Internal
0.01 NPLC
Digital I/O
0.1 NPLC
Internal
0.1 NPLC
Digital I/O
1.0 NPLC
Internal
1.0 NPLC
Digital I/O
Maximum single measurement rates (operations per second) for 60 Hz (50 Hz):
A/D converter speed
Trigger origin
0.001 NPLC
0.01 NPLC
0.1 NPLC
1.0 NPLC
20
Tests performed with a Model 2602B using the following equipment: Computer hardware (Intel
Instruments™ PCI-GPIB); driver (NI-488.2 Version 2.2 PCI-GPIB); software (Microsoft
version 4.1).
21
Exclude current measurement ranges less than 1 mA.
Specifications are subject to change without notice
8 of 13
20,21
Measure to
Measure to
memory
GPIB
(using user
(using user
scripts)
scripts)
20000
9800
(20000)
(9800)
8100
7100
(8100)
(7100)
4900
3900
(4000)
(3400)
3500
3400
(3100)
(3000)
580
560
(480)
(470)
550
550
(460)
(460)
59
59
(49)
(49)
59
59
(49)
(49)
Measure to GPIB
Internal
1900 (1800)
Internal
1450 (1400)
Internal
450 (390)
Internal
58 (48)
®
Instrument Specifications
Source
Source
measure to
measure to
memory
GPIB
(using user
(using user
scripts)
scripts)
7000
6200
(7000)
(6200)
5500
5100
(5500)
(5100)
3400
3200
(3000)
(2900)
3000
2900
(2700)
(2600)
550
550
(465)
(460)
540
540
(450)
(450)
59
59
(49)
(49)
59
59
(49)
(49)
Source measure to
GPIB
1400 (1400)
1200 (1200)
425 (370)
57 (48)
®
Windows
Source
measure to
memory
(using sweep
API)
12000
(12000)
11200
(11200)
4200
(3700)
4150
(3650)
560
(470)
560
(470)
59
(49)
59
(49)
Source measure
pass/fail to GPIB
1400 (1400)
1100 (1100)
425 (375)
57 (48)
®
®
Pentium
4 2.4 GHz, 2 GB RAM, National
®
®
XP, Microsoft
Visual Studio
SPEC-2602B Rev. B / February 2014
Source
measure to
GPIB
(using sweep
API)
5900
(5900)
5700
(5700)
4000
(3500)
3800
(3400)
545
(460)
545
(460)
59
(49)
59
(49)
®