Page 1
PWR-190-AC/DC, PWR-2190-AC/DC Quick Installation Guide AC/DC Power Module Edition 4.0, March 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Moxa China (Shanghai office): Toll-free: 1-888-669-2872 Toll-free: 800-820-5036 Tel: 1-714-528-6777 Tel: +86-21-5258-9955 Fax: 1-714-528-6778 Fax: +86-21-5258-5505 Moxa Europe: Moxa Asia-Pacific: Tel:...
Page 2
Introduction The PWR-190-AC/DC and PWR-2190-AC/DC power modules are designed for the NRack Systems’ TRC-190/2190 chassis. They transform the AC power input into a steady 12 VDC, or DC power input from 36 to 53 VDC to a steady 12 VDC output to power the slide-in modules for the TRC-190.
Page 3
PWR-190/2190-DC Powering the AC/DC Power Supply Module ATTENTION Ensure before connecting to the external power source, the ON/OFF switch must be set to “O”. Failure to observe this caution could result in damage to, and subsequent failure of, the power supply module and human life.
Page 4
PWR-190/2190-DC 1. Set the ON/OFF switch to “O”. 2. Be sure that the external power source is NOT powered. 3. Connect the power cord and the shielding ground to the male terminal block. 4. Link the male and female terminal blocks. 5.
Page 5
3. After removing the plate from the chassis, slowly slide the power supply module into the chassis. Push the power supply module into the chassis to ensure that it is all the way inside and firmly connected to the chassis. PWR-190/2190-AC PWR-190/2190-DC 4.
Page 6
Replacing the Power Supply Fuses(PWR-190/2190-AC module only) You do not need to remove the power supply module from the chassis in order to replace the fuse in the module. ATTENTION Wear a grounding device and observe electrostatic discharge precautions when replacing the fuse in the power supply module. Failure to observe this caution could result in damage to, and subsequent failure of, the power supply module.
Specifications Physical Characteristics Case SECC (1.2 mm) Dimensions 157.4 x 123.3 x 70 mm (18.6 x 11 x 3.3 in.) Gross Weight 0.5 kg or 1.1 lbs Environment Operating Temperature 0 to 60°C (32 to 140°F) Operating Humidity 5% to 95% RH Storage Temperature -40 to 85°C (-40 to 185°F) Power Requirement...
Need help?
Do you have a question about the PWR-190-AC/DC and is the answer not in the manual?
Questions and answers