Troubleshooting Guide - Hatco FLAV-R-FRESH FDWD Series Installation And Operating Manual

Holding and display cabinets
Hide thumbs Also See for FLAV-R-FRESH FDWD Series:
Table of Contents

Advertisement

WARNING
To avoid any injury or damage, the unit must be
serviced by qualified personnel only.
SYMPTOM
Unit is energized, but display
lights do not work.
Unit operates, but is not
circulating air inside cabinet.
Unit is plugged in, but
nothing works.
Unit
is
operational,
revolving
rack
(if
equipped) does not turn.
Form No. FDWDM-1207
All manuals and user guides at all-guides.com
PROBABLE CAUSE
Light bulb is burned out or
loose.
Blower wires are loose or
disconnected.
The correct voltage may not
be supplied to blower.
No power to unit.
Power cord connections are
loose or disconnected.
Power cord is damaged.
Defective ON/OFF switch.
but
Incorrect voltage is supplied
so
to rack motor.
Proximity magnet or proximity
switch not working properly.
NOTE: TROUBLESHOOTING GUIDE continued on next page.

TROUBLESHOOTING GUIDE

To prevent electric shock or injury, turn the
POWER switch OFF, unplug the unit from the
power source, and allow to cool completely
before performing any maintenance or cleaning.
CORRECTIVE ACTION
Check light bulb. If burned out, replace. If
loose, tighten.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Check electrical receptacle and verify
that power supply matches specifications
on unit. If receptacle is not working, check
circuit breaker and reset, or plug unit into
a different known working receptacle.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
Contact Authorized Service Agent or
Hatco for assistance.
13
WARNING