DRAINING THE RESERVOIR

WARNING
To avoid any injury, turn the power OFF to the
unit and allow to cool before draining.
It is recommended that the Flav-R-Fresh
reservoir be drained prior to moving the cabinet and
after removing lime or mineral deposits from the
water reservoir.
To drain the reservoir, locate the valve on the
underside of the ceiling sheet. Position a one gallon
(four liter) container under the valve. Turn the valve
handle from the horizontal position (closed) to the
vertical position (open). Once the reservoir is empty,
return handle to the closed position.
Valve
Open
Figure 11. Draining Reservoir Valve
NOTE: If the water used has an excessive amount
of lime or mineral content, follow the
REMOVING
LIME
DEPOSITS procedure for periodic cleaning
and deliming of the water reservoir.
NOTICE
Water Quality Requirement — Incoming water in
excess of 3.0 grains of hardness per gallon
(GPG) (0.75 grains of hardness per liter) must be
treated and softened before being used. Water
containing over 3.0 GPG (0.75 GPL) will
decrease the efficiency and reduce the
operating life of the unit.
NOTE: Product failure caused by liming or
sediment buildup is not covered under
warranty.
Form No. FDWDM-1207
All manuals and user guides at all-guides.com
water
®
Valve
Closed
AND
MINERAL
REMOVING
LIME
DEPOSITS
1. Turn off the unit and unplug the unit from its
power source.
2. After the unit has cooled down, drain all
remaining water out of the unit.
3. Fill the unit with a mixture of 75% water and 25%
off-the-shelf vinegar.
NOTE: It is recommended that this procedure be
performed when the unit will not by used for
a period of time, such as the end of the day.
4. Plug the unit into the correct power source and
turn on the unit.
5. With both the humidity and heat settings on high,
allow the unit to run for 30 minutes.
6. After the deliming period, turn off the unit, unplug
it from the power source, and allow it to cool
7. Drain the solution from the unit (refer to the
DRAINING THE RESERVOIR procedure).
8. Continue to fill and drain the unit with water until
the discharge is clear and all deliming solution
has been removed and rinsed through.
9. Plug the cabinet power cord into its power source
and fill the unit as usual for daily operation.
NOTE: The lime and mineral content of the water
used for daily operation will determine how
often this procedure must be performed.