Maintenance; General; Cleaning - Hatco FLAV-R-FRESH FDWD Series Installation And Operating Manual

Holding and display cabinets
Hide thumbs Also See for FLAV-R-FRESH FDWD Series:
Table of Contents

Advertisement

MAINTENANCE

GENERAL

The Hatco Flav-R-Fresh
Cabinets are designed for maximum durability and
performance with minimum maintenance. The rack
motor and blower motor are permanently lubricated
and require no maintenance.

CLEANING

WARNING
To prevent electric shock or injury, turn the
POWER switch OFF, unplug the unit from the
power source and allow to cool completely
before performing any maintenance or cleaning.
WARNING
To prevent any injury, discontinue use if power
cord is frayed or worn.
Hatco Flav-R-Fresh
cabinets are made of stainless
®
steel and aluminum. To preserve the bright finish, it
is recommended that the exterior and interior
surfaces be wiped daily with a damp cloth. Food
pans should be removed and washed. Stubborn
stains may be removed with a good stainless steel
cleaner or a non-abrasive cleaner.
NOTICE
Use non-abrasive cleaners only. Abrasive
cleaners could scratch the finish of your Flav-R-
Fresh
Holding and Display Cabinet marring its
®
appearance and making it susceptible to soil
accumulation.
Clean the glass sides using a common glass
cleaner. For hard-to-clean stains, removal of the
glass is suggested.
RemovIng the Glass
1. Lift the glass to be cleaned out of the bottom
channel of the cabinet.
2. Pull the lower edge away from the cabinet.
3. Carefully lower the glass until the top clears the
cabinet.
Replacing the Glass
1. Position the glass with the top edge under the
cabinet lip and raise the glass until it clears the
bottom channel of the cabinet.
2. Move the bottom of the glass towards the cabinet
until the glass rests against the cabinet frame.
3. Carefully lower the glass until it rests in the
bottom channel of the cabinet.
All manuals and user guides at all-guides.com
Holding and Display
®
Removing the Rotating Rack for Cleaning
(Models FDWD-1 and FDWD-2)
1. Open the front access door.
2. Remove the two (2) connecting pins from the
connecting coupling located at the top of the rack
inside the cabinet (see Figure 10.).
3. Lower the connecting coupling until it is free of
the motor shaft and remove the rack from the
cabinet.
Connecting
Pin
Bottom
Point
Figure 10. Removing Motorized Display Racks
Replacing the Rotating Rack
1. With the connecting coupling in position on the
top rack shaft, insert the rack into the cabinet
through the access door and place the rack
bottom point in the dimple located at the center
of the cabinet floor.
2. Slide the connecting coupling up onto the motor
shaft and align the coupling holes.
3. Insert the two (2) connecting pins. The top
connecting pin goes through the connecting
coupling and the motor shaft. The bottom
connecting pin goes through the connecting
coupling and the rack shaft.
10
Connecting
Coupling
Rack
Shaft
Form No. FDWDM-1207

Advertisement

Table of Contents
loading

Table of Contents