Hatco FLAV-R-FRESH FDWD Series Installation And Operating Manual
Hatco FLAV-R-FRESH FDWD Series Installation And Operating Manual

Hatco FLAV-R-FRESH FDWD Series Installation And Operating Manual

Holding and display cabinets
Hide thumbs Also See for FLAV-R-FRESH FDWD Series:

Advertisement

Holding and Display Cabinets
This manual contains important safety information
concerning the maintenance, use and operation of
this product. Failure to follow the instructions
contained in this manual may result in serious
injury. If you're unable to understand the contents
of this manual, please bring it to the attention of
your supervisor. Do not operate this equipment
unless you have read and understood the contents
of this manual. Keep this manual in a safe location
for future reference.
All manuals and user guides at all-guides.com
FLAV-R-FRESH
FDWD Series
Installation and
Operating Manual
I&W #07.05.177.00
®
Este manual contiene importante información
sobre seguridad concerniente al mantenimiento,
uso y operación de este producto. Cualquier falla
en el seguimiento de las instrucciones contenidas
en este manual puede resultar en un serio daño.
Si usted no puede entender el contenido de este
manual por favor pregunte a su supervisor. No
opere este equipo al menos que haya leído y
comprendido el contenido de este manual.
Almacenar este manual en una localización
segura para la referencia futura.
© 2007 Hatco Corporation

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLAV-R-FRESH FDWD Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hatco FLAV-R-FRESH FDWD Series

  • Page 1 Keep this manual in a safe location for future reference. Almacenar este manual en una localización segura para la referencia futura. © 2007 Hatco Corporation...
  • Page 2: Table Of Contents

    Hatco Holding and Display the humidity level. The use of controlled, Cabinet. Safety instructions that appear in this...
  • Page 3: Important Safety Information

    Hatco equipment. To avoid any injury, turn the POWER switch It is essential to use Genuine Hatco OFF and allow the unit to cool before Replacement Parts when repairing Hatco draining.
  • Page 4: Model Designation

    All manuals and user guides at all-guides.com IMPORTANT SAFETY INFORMATION NOTICE NOTICE Water Quality Requirements – Incoming water in Do not use deionized water. Deionized water will excess of 3.0 grains of hardness per gallon greatly shorten the life of the water pan and (GPG) (0.75 grains of hardness per liter) must be heating element.
  • Page 5: Model Descriptions

    All manuals and user guides at all-guides.com MODEL DESCRIPTIONS ALL MODELS All display cabinets have an air heating system, humidity system with low water control protection, incandescent lights, tempered glass sides, and a door. The standard access door can be hinged left or right.
  • Page 6: Specifications

    If the plug and receptacle do not match, contact AS 3112 CEE 7/7 Schuko a qualified electrician to determine and install the proper voltage and size electrical outlet. NOTE: Receptacle not supplied by Hatco. Figure 4. Plug Configurations ELECTRICAL RATING CHART Model Voltage...
  • Page 7: Installation

    All manuals and user guides at all-guides.com INSTALLATION UNPACKING LOCATION The Flav-R-Fresh Holding and Display Cabinets ® are shipped with most components installed and CAUTION To avoid any injury or damage, locate the ready for operation. The following installation display cabinet at the proper counter height in instructions must be performed before plugging in an area that is convenient for use.
  • Page 8: Reversible Access Door

    All manuals and user guides at all-guides.com INSTALLATION REVERSIBLE ACCESS DOOR 7. Install the hinges on the opposite side of the cabinet where the striker plates were previously The Flav-R-Fresh access door may be hinged on ® mounted using the original hinge mounting either the left or right side for your convenience (see screws.
  • Page 9: Relocating The Proximity Switch

    All manuals and user guides at all-guides.com INSTALLATION RELOCATING THE PROXIMITY SWITCH 5. Remove the screw and nut from the new mounting hole. Secure the proximity switch to the (Rotating Rack Models Only — mounting hole with the screw and nut. Make sure FDWD-1 and FDWD-2) to maintain switch orientation when tightening hardware.
  • Page 10: Operation

    All manuals and user guides at all-guides.com OPERATION GENERAL Use of softened or distilled water is recommended to preserve the life of the electrical and mechanical 1. Plug the cabinet into a properly grounded components in the reservoir. Do not use deionized electrical outlet of the correct voltage, size, and water.
  • Page 11: Food Holding Guide

    CABINET TEMPERATURE display shows the lowest temperature point inside the cabinet, not the WARNING Hatco Corporation is not responsible for the product temperature. actual food product serving temperature. It is Allow 20 minutes to preheat a full reservoir of water.
  • Page 12: Maintenance

    All manuals and user guides at all-guides.com MAINTENANCE GENERAL Removing the Rotating Rack for Cleaning (Models FDWD-1 and FDWD-2) The Hatco Flav-R-Fresh Holding and Display ® 1. Open the front access door. Cabinets are designed for maximum durability and performance with minimum maintenance. The rack 2.
  • Page 13: Draining The Reservoir

    All manuals and user guides at all-guides.com MAINTENANCE DRAINING THE RESERVOIR REMOVING LIME MINERAL DEPOSITS 1. Turn off the unit and unplug the unit from its WARNING To avoid any injury, turn the power OFF to the power source. unit and allow to cool before draining. 2.
  • Page 14: Display Light Bulb Replacement

    120 Volt applications, use Hatco part number characteristics that will allow them to operate 02.30.043.00. For 220 or 240 Volt applications, use safely in Hatco equipment. It is essential to use Hatco part number 02.30.058.00. Genuine Hatco Replacement Parts when repairing Hatco equipment.
  • Page 15: Troubleshooting Guide

    Unit operates, but is not Blower wires are loose or Contact Authorized Service Agent or circulating air inside cabinet. disconnected. Hatco for assistance. The correct voltage may not Contact Authorized Service Agent or be supplied to blower. Hatco for assistance.
  • Page 16 Unit is not producing any Safety high-limit is tripped or Contact Authorized Service Agent or “hot air” inside cabinet. open. Hatco for assistance. Incorrect voltage supplied to Contact Authorized Service Agent or heating element. Hatco for assistance. Blower motor is not working.
  • Page 17: Accessories

    All manuals and user guides at all-guides.com ACCESSORIES DISPLAY RACKS 4″ (102 MM) ADJUSTABLE LEGS A nickel-plated 4-tier circle rack, a nickel-plated The 4″ (102 mm) adjustable legs are used to add 4-shelf multi-purpose rack, a nickel-plated 4-shelf additional height to the unit. angle rack, and a stainless steel pretzel tree are 1.
  • Page 18 Three-Piece Sign Holder or the One-Piece Sign Holder. 3. Place the new cabinet hood/sign holder NOTE: Signage not supplied by Hatco. Sign assembly over the mounting holes. dimensions 19-1/16″ w (484 mm) x 3-1/4″ h 4. Reinsert the four hood mounting screws through (83 mm) x 1/16″...
  • Page 19: Hatco Limited Warranty

    One (1) Year Parts and Labor PLUS Four accept or reject any such claim in whole or in part. (4) Years Parts-Only Warranty on Hatco will not accept the return of any Product pro-rated terms that Hatco will explain without prior written approval from Hatco, and all at Buyer’s request:...
  • Page 20: Authorized Parts Distributors

    All manuals and user guides at all-guides.com HATCO AUTHORIZED PARTS DISTRIBUTORS ALABAMA NEW YORK TEXAS IOWA Jones McLeod Appl. Svc. Acme American Repairs, Inc. GCS Service Electric Motor Service Co. Birmingham 205-251-0159 Brooklyn 718-456-6544 Fort Worth 817-831-0381 Davenport 319-323-1823 ARIZONA Alpro Service Co.

Table of Contents