Overview Of The Receiver - Bellfires Box Gas Panorama 45 Installation And Maintenance Manual

Table of Contents

Advertisement

Description
2 2 .7.4

Overview of the receiver

A
B
C
D
E
F
G
H
I
J
K
14
Item
Reset button
Connection for an adapter
connection for external operating
8 wire cable connection
Thermocouple voltage / current IN (red con-
nection)
Thermocouple voltage / current OUT (yellow
connection)
Piezo cable connection
Connection to the gas valve rear burner
(AUX)
Battery compartment cover
Connection for a wifi-box (SI)
Connection for the fan/light module (MOD-
ULE)
Description
Reset of the receiver
Optionally, a 6 VDC adapter can supply the
receiver and an optional wifi-box with power
Optionally, a wall switch or domotica system
can be connected
Sends signals to the gas regulator block
Connection to the thermoelectric pilot light
shut-off wire IN
Connection to the thermoelectric pilot light
shut-off wire OUT
Connection for the piezo cable which is con-
nected to the ignition electrode of the pilot
light
Sends a signal if the rear burner must burn
Batteries are not applicable in the receiver for
this appliance. (Power is supplied by the fan/
light module.)
Optionally, a wifi-box can be connected to the
receiver to control the appliance with a smart-
phone or tablet with the Bellfires app
To control the light function
Box Gas Panorama 45/45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Box gas panorama 45 mfSmart bell panorama 45/45 mf