Grounding; Ground Points - Ford TRANSIT 2016.75 Mounting Manual

Body and equipment mounting
Table of Contents

Advertisement

4.20 Grounding

4.20.1 Ground Points

WARNING: It is recommended to only use
one eyelet per stud for high current
applications. If more than one eyelet per
stud is unavoidable, the highest current
eyelet feed should be connected closest
to the supply terminal. Do not exceed two
eyelets or crimp terminals per stud
connection. See figures E228188,
E228189 and the following table for
recommended ground points that can be
used.
CAUTIONS:
Only use the ground points indicated.
Using alternative points may affect the
vehicle integrity.
Van, Bus, Kombi Ground Points
40
7
8
39
34
33
32
4
5
3 36 2
E228188
E167589
EU
FORD TRANSIT 2016.75
13
15
16
14
24 22 23
1
6
9 10 12 11 17 18 19 20 21
1
2
Make sure that all ground points are
tightened to the correct torque.
NOTE: The Ground Point (GP) numbers are only
for reference to show the location of the GP.
Ground wires should be brought back to the Ford
ground points provided, please refer to the
following figures. For very high current users, it is
recommended that the ground connection is
made directly to the ground point close to the
battery ground point. An auxiliary ground stud
eyelet can be ordered
Refer to: 4.4 Battery and Cables (page 110).
Additional Loads and Charging Systems section
for additional information.
44 45 42
25
41 43
36
E222645
29
30 31
48
26
27 28
5
3
4
Date of Publication: 03/2018
35
219

Advertisement

Table of Contents
loading

Table of Contents