Battery Rules - Ford TRANSIT 2016.75 Mounting Manual

Body and equipment mounting
Table of Contents

Advertisement

Battery Part Numbers and Usage
Battery Part Number
Single Battery FWD (without Start-Stop)^
GK2T-10655-D*
Single Battery FWD (without Start-Stop)^^
GK2T-10655-E*
Single Battery FWD (with Start-Stop)
DV6T-10655-B*
Single Battery RWD (with/without Start-Stop)
DV6T-10655-B*
Twin Battery (without Start-Stop)^
GK2T-10655-D*
Twin Battery (without Start-Stop)^^
GK2T-10655-E*
Twin Battery (with Start-Stop)
DV6T-10655-B*
High Performance Deep Cycle AGM Batteries (OW5)
8C1V-10655-A*
^ 2 year warranty territories, ^^3 year warranty territories

4.4.3 Battery Rules

• Batteries in parallel must be of the same type
and capacity and listed in the Ford battery
table.
• Third party batteries and loads are to be
isolated from the standard Ford system at key
off.
• For external charging of batteries ensure that
the maximum voltage of 15.2V is not exceeded.
Normal proprietary charging equipment should
operate below this voltage.
NOTE: Charge balance calculations are required
when adding additional systems taking into
account alternator size and battery capacity. On
battery choice a number of factors are important:
114
Date of Publication: 03/2018
Type
750 CCA (80Ah @20 hour rate) Standard
Flooded Battery
710 CCA (75Ah @20 hour rate) Enhanced
Flooded Battery
800 CCA (80Ah @ 20 hour rate)
Absorbent Glass Mat Battery
800 CCA (80Ah @ 20 hour rate)
Absorbent Glass Mat Battery
750 CCA (80Ah @20 hour rate) Standard
Flooded Battery
710 CCA (75Ah @20 hour rate) Enhanced
Flooded Battery
800 CCA (80Ah @ 20 hour rate)
Absorbent Glass Mat Battery
850 CCA (95Ah @ 20 hour rate) Absorbent
Glass Mat Battery
Quantity
2
2
2
2
Important Factors for Battery Choice
• Battery specification capability in ampere hours
for continuously loading until empty. For
example: an 95Ah fully charged battery can
supply 4.75 Ampere over a 20 hour period at 20
degrees centigrade until it is fully discharged.
• The Cold Crank Ampere (CCA) rating is the
maximum rating for cold start requirements.
• For deep cycling and micro cycling requirements
(engine off loads) the deep cycle battery
system (OW5) is recommended.
Extra batteries added to the power supply should
be connected as shown at the end of this section.
Size
1
H7
1
H7
1
H7
1
H7
H7
H7
H7
H8
FORD TRANSIT 2016.75
EU

Advertisement

Table of Contents
loading