Camper And Ford Skeletal Chassis Central Connectors - Ford TRANSIT 2016.75 Mounting Manual

Body and equipment mounting
Table of Contents

Advertisement

WARNING: Only use the Ford approved
kit for adding fuses to the customer
connection points.
CAUTION: When connecting to the
customer connection points, it is
recommended to disconnect the battery
ground so as to avoid a short circuit. The
fixing torque (M5) is 3.5–4.5 Nm.
NOTE: When fitting additional power wiring feeds
the protective cover will need to be revised to
allow routing for the extra wires. The cover is pre
marked with the relevant areas so that they can
be easily removed.
NOTE: There is a maximum of three customer
connection points, each capable of supplying a
max current of 60 Ampere (A). These points are
always located on the driver's seat pedestal and
are protected by a cover.
NOTE: Vehicles with Single Battery without Aux
Fuse Panel will only have one customer connection
points fitted, the remaining two can be used after
fitting the customer connection point kit
KTBK2T-14B475-A* .
NOTE: Camper vehicles and Ford Skeletal Chassis
have no pre-installed CCP. One can be used after
fitting the CCP kit KTBK2T-14B475-A*; the other
two are internally used and should not be touched.
E169183
Item
A
C2-1 - 15 way connector (face view)
B
C2-2 - 6 way connector (face view)
C
C2-3 - KL30 connector (face view) 60A Fed from Pre Fuse Box + Ground
192
Date of Publication: 03/2018
A
1
3
A
B
C
Description
Contact your local Ford dealer or National Sales
Company representative for details of the kit.
E145358 shows the left hand drive situation. On a
right hand drive vehicle the pre fuse box is rotated
180 degrees. Therefore C1/F12 will be at the
bottom and C3/F14 at the top connections.
For High Current Supply and Ground Connections
Refer to: 4.4 Battery and Cables (page 110).
4.19.3 Camper and Ford Skeletal
Chassis Central Connectors
WARNING: If multiple systems are to use
this supply, the total system load must
not exceed the 60A short term loading.
NOTE: There is no supply (60A) from the
Customer Connection Points on the drivers seat
pedestal, instead there are dedicated Camper
Connectors which are located in the passenger
seat, see figure E169183. This includes a 60A
supply and ground.
For additional information
Refer to: 4.1 Wiring Installation and Routing Guides
(page 85).
Wiring Specification table for characteristics on
continuous loads versus temperature.
B
13
1
4
6
15
3
C
1
2
FORD TRANSIT 2016.75
EU

Advertisement

Table of Contents
loading

Table of Contents