Smeg Gas Cooktop PA106SX Instructions For Installation And Use Manual page 19

Smeg gas cooktop instructions for installation and use
Hide thumbs Also See for Gas Cooktop PA106SX:
Table of Contents

Advertisement

8.2
Adjustment for ULPG
Check that the connection has been made as
described in the "Gas connection" section.
Undo the screw "C" and push the air regulator "D"
fully down. Use a spanner to remove the nozzles
"E" and fit those of suitable type following the
instructions given in the tables for bottled gas
ULPG 2.75 kPa. The nozzle must not be
tightened to a torque of over 3 Nm.
Burner
Auxiliary (1)
Semi rapid (2)
Medium rapid (3)
Large rapid (4)
Ultra rapid (5)
CAUTION: for references A and B on the left
UR and right UR burners, see drawings at
side.
8.3
Adjustment for natural gas
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
To allow the unit to work back with this type of gas, after it has been adjusted for
ULPG, perform the same operations described in paragraph "8.2 Adjustment for
ULPG", but refer to the following table for the proper injectors.
Instructions for the installer
Nominal gas
Consumption (MJ/h)
3.9
6.3
9.0
10.8
A
13.5
B
ULPG – 2.75 kPa
Injector
(mm)
0.54
0.65
0.78
0.85
0.82
0.54
21

Advertisement

Table of Contents
loading