  • Page 1 Innovations for clean water ® BASIC / CLASSIC AQUAmax Operation and maintenance manual...
  • Page 3: Table Of Contents

    AQUAmax small wastewater treatment plant. Please observe that the maintenance are very important for a good treatment performance. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 3 from 40...
  • Page 4: General And Safety Information

    The correct function can only be guaranteed with the employment of original spare parts or spare parts approved by ATB. Before commissioning, all points of the operating instructions are to be checked. Keep these instructions readily to hand at all times! ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /...
  • Page 5 Danger due to electrical voltage! Rotating parts. Danger of crushing and being drawn into the area of the submersible aerator! ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 5 from 40...
  • Page 6: Functional Description

    The water streams with this are fed into the individual areas using a patented hydraulic system. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 6 from 40...
  • Page 7 AQUAmax BASIC or AQUAmax CLASSIC forms the basic framework for the phosphate removal and UV disinfection (CLASSIC only). ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 7 from 40...
  • Page 8: Control Unit Atbcontrol © 3

    © Should the ATBcontrol 3 be used for other purposes without the express approval of ATB WATER GmbH and/or if the following safety information is disregarded, this can lead to malfunction of or defects in the plant. In this case any liability is ruled out.
  • Page 9: General Information On Operation

    Attention is to be paid to correct laying of the protective earth conductor up to the earthing of the building. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 9 from 40...
  • Page 10: Commissioning

    (not the serial number of the control unit), here. Please ensure that the serial number is entered right-aligned, in order that leading zeros result. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 10 from 40...
  • Page 11 Have you made an incorrect input? By selecting OK the commissioning can be repeated. If the inputs are correct, confirm with ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 11 from 40...
  • Page 12: Main Level

    Return using OK. Run times You can have the run times shown in a weekly summary over complete operating time. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 12 from 40...
  • Page 13: Settings

    ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 13 from 40...
  • Page 14 Following successful activation this function is blocked for six months. Signal sound Selection of the volume of the alarm sound. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 14 from 40...
  • Page 15: Service Mode

    Please ensure that the serial number is entered right-aligned, in order that leading zeros result. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 15 from 40...
  • Page 16: Manual Operation / Info

    Under this point you can call up the details for the selected type, the PT value set, the version number and the date of commissioning. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 16 from 40...
  • Page 17: Date/Time / Language / Error Reset

    If this is not wanted, i.e. the error should be reported immediately with the next occurrence, press OK. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 17 from 40...
  • Page 18: Pre-Set Parameters

    ** For the ZB variants (pressure aeration), the parameters for 60 and 75 PE must be entered manually! ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 18 from 40...
  • Page 19: Current Limiting Values

    Adjustments do not have to be undertaken. A power failure is recorded in the logbook. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 19 from 40...
  • Page 20: Usb-Connection

    Should an exchange of fuses be necessary the control unit MUST be disconnected from the mains beforehand! ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 20 from 40...
  • Page 21: Potential-Free Contact

    12V DC Float 12V feed Float 12V feed White 12V DC Float return Float return (blue) Yellow/ PE earth PE earth green conductor conductor ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 21 from 40...
  • Page 22: Technical Data

    The exchange of the accumulators with batteries is forbidden due to the danger of explosion! ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 22 from 40...
  • Page 23 ® Operation and maintenance manual AQUAmax BASIC/CLASSIC ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 23 from 40...
  • Page 24: Information On Routine Maintenance

    Frequently, the lower water authorities demand the sending of the maintenance report by the operator or maintenance firm, after each routine maintenance. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 24 from 40...
  • Page 25: Self-Monitoring By The Operator

    At the conclusion of the desludging the primary settling stage is to be so far filled ® again with water that the outlet opening of the AQUAmax is fully submerged! ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 25 from 40...
  • Page 26: Information On Disposal

    Block wastewater treatment plants Collection points Wastes containing oil (oil filters, Poison wastewater Collection points clothes etc.) WC stones Poison wastewater Do not use ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 26 from 40...
  • Page 27: Rectification Of Faults

    • The hydraulic system in the • Call Service. ® AQUAmax for the interruption of the charging pipeline is impaired. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 27 from 40...
  • Page 28 (check power consumption). • The corresponding • Call Service. electrical unit is defective. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 28 from 40...
  • Page 29: Important Data For Fault Diagnosis Of The Electrical Units

    Submersible motor pumps ATBlift 1 0.25 ATBlift 2 1.25 0.30 NOVA 180 SV 0.24 NOVA 200 SV 0.35 FEKA 600 ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 29 from 40...
  • Page 30: Operations Diary

    In order to document the self-monitoring you are obligated to keep the operations diary according to the requirement from the National General Technical Approval. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 30 from 40...
  • Page 31 Additional operating diaries can be obtained from your installation partner or under www.atbwater.com ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 31 from 40...
  • Page 32 In order to document the self-monitoring you are obligated to keep the operations diary according to the requirement from the National General Technical Approval. ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 32 from 40...
  • Page 33 Additional operating diaries can be obtained from your installation partner or under www.atbwater.com ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com / Art.-No.: 9060 0210 / Status: 30.01.2019 / Page 33 from 40...
  • Page 34 NB 0992 also declaration of performance (DoP) ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica EN 12566-3:2016 Packaged domestic wastewater treatment plant for treatment of domestic wastewater ® AQUAmax Material Concrete Effectiveness of treatment: Treatment efficiency (at tested 91,6 %...
  • Page 35 NB 1739 also declaration of performance (DoP) ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica EN 12566-3:2016 Packaged domestic wastewater treatment plant for treatment of domestic wastewater ® AQUAmax Material PE (Type N and A) Effectiveness of treatment: Treatment efficiency (at tested...
  • Page 36 NB 0992 also declaration of performance (DoP) ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica EN 12566-3:2016 Packaged domestic wastewater treatment plant for treatment of domestic wastewater ® AQUAmax Material PE (Type R) Effectiveness of treatment: Treatment efficiency (at tested...
  • Page 37 NB 1739 also declaration of performance (DoP) ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica EN 12566-3:2016 Packaged domestic wastewater treatment plant for treatment of domestic wastewater ® AQUAmax Material Effectiveness of treatment: Treatment efficiency (at tested 85,5 % organic daily load BOD...
  • Page 38: Ec Declaration Of Conformity

    Declaration of EC-conformity ATB Umwelttechnologien GmbH The manufacturer: Südstr. 2 D-32457 Porta Westfalica ® declares herewith, that the following AQUAmax specified product: 2006/42/EG Directive on machinery implements the requests of following EC- 2014/30/EU Directive to Directives: electromagnetic compatibility 2014/35/EU Directive to electrical...
  • Page 40 ® Operation and Maintenance Manual AQUAmax BASIC/CLASSIC / Art.-No.: 9060 0210 / Status: 30.01.2019...