Technical Data; Warranty - Gira System 3000 Operating Instructions Manual

Blind control insert with auxiliary input
Hide thumbs Also See for System 3000:

Advertisement

System 3000
Blind control insert with auxiliary input
Implementing a wind alarm
Wind sensors serve to protect a Venetian blind from being destroyed by a strong wind. The
Venetian blind is moved to a safe end position and locked there until the wind drops below the
set threshold value.
Connect the wind sensor (8) according to the connection example (Figure 6). The wind
alarm is implemented via extension input 2.
In order to use the wind alarm for all external Venetian blinds of a building, the wind
sensor must be connected to extension unit input 2 of the master control.
As long as an Up command is active on extension unit input 2, the Venetian blind cannot
be operated either manually or automatically.
6

Technical data

Rated voltage
Mains frequency
Standby load: 0.1...0.5 W, depending on the cover
Ambient temperature
Storage/transport temperature
Running time
Connected load
Motors
Data according to EN 60730-1
Action
Degree of soiling
Measured surge voltage
7

Warranty

The warranty is provided in accordance with statutory requirements via the specialist trade.
Please submit or send faulty devices postage paid together with an error description to your re-
sponsible salesperson (specialist trade/installation company/electrical specialist trade). They will
forward the devices to the Gira Service Center.
82595612
Figure 6: Connection example of wind sensor
06.03.2019
AC 230 V~
50 / 60 Hz
-5 ... +45 °C
-20 ... +70 °C
approx. 120 s
700 W
1.B
2
4000 V
5 / 6