Operating Statuses/General Messages - DEMAG DC-Com 1 Operating Instructions Manual

Hide thumbs Also See for DC-Com 1:
Table of Contents

Advertisement

Fig. 71
Safety function failure
If a safety function fails, the equipment must not be operated until it is repaired.
Malfunctions
The chain hoist can only function when it is correctly connected to the power supply. In the event of a failure,
therefore, first check cables, strain relief and power supply connections. Malfunctions may also be caused by in‐
correct transmission of commands from the control pendant. Therefore, check the control pendant and the control
cable for damage and the plug-in connector on the pendant and in the service enclosure for correct fit.
The symbols are shown one after the other.
● Please contact our after-sales service if the cause of the fault cannot be eliminated with the given measures.
9.3

Operating statuses/general messages

Fig. 72
Item
Display
Malfunction/event
1
No lifting, no lowering.
2
No lifting, no lowering.
3
-
No lifting, no lowering.
4
-
5
-
6
-
7
-
8
-
9
-
Tab. 68
Error messages start with an "E" for error.
Before any further movement is possible, the error message must be
acknowledged using the emergency stop.
Possible cause
No power supply (display is dark)
Emergency stop actuated.
Cables not connected or defective.
Plug connections not connected or defective.
-
Incorrect motor direction of rotation.
Thermal contact open.
Upper or lower limit position has been reached.
When the voltage is switched on or the emergency-
stop is unlocked, a button is already actuated.
Control cable interrupted.
-
-
-
-
-
-
Remark
Check mains connection and fuse link; check connection
cable for interruption; check mains connector in the service
enclosure. Check PE phase for correct connection.
Unlock emergency stop by turning it.
Check and replace connections, as required.
Check and replace plug connections, as required.
Flashing: READY
Two phases of the mains connection cable must be
changed. First disconnect unit from the power supply.
Check motor plug connector X8 for continuity between ter‐
minals 4 and 8.
Actuate opposite direction.
Release button and actuate it again.
Check connections of the control cable on the pendant and
in the service enclosure. Check control cable for continuity.
Operating mode: Lifting V1
Operating mode: Lowering V1
Operating mode: Lifting V2
Operating mode: Lowering V2
Operating mode: Lifting start-up
Operating mode: Lowering start-up
97