Mobile Control System - DEMAG DC-Com 1 Operating Instructions Manual

Hide thumbs Also See for DC-Com 1:
Table of Contents

Advertisement

5.6.4

Mobile control system

Fig. 16
Fig. 17
38
Item
Designation
1
11-pole + PE flat cable
2
Connector enclosure cpl.
3
Connector adapter cpl.
4
Cable collector
5
DSE-10C control pendant
6
Control cable locking mechanism
Tab. 25
H4, H5, H8, H11 height-adjustable standard control cables are used to‐
gether with the cable collector.
X40 plug connector pin assignment
Signal
Cond.
-
PE
-
Special 2 (horn)
Left
Lifting
Emergency stop
Forwards
Tab. 26
Component parts
comprising
Socket enclosure
Mounting frame
VC-AMS8 pin insert
Flat cable union
Bayonet lock
VC-MP-1-R-M25 bush enclosure
VC-TR1/2M bush frame
VC-TFS8 socket insert
PIN
Cond.
-
B4
B8
11
Reference potential (24 V)
PE
B3
B7
-
-
B2
B6
-
8
B1
B5
10
4
A4
A8
7
3
A3
A7
9
2
A2
A6
6
1
A1
A5
5
Order no.
720 139 45
720 187 45
720 087 45
720 065 45
773 352 45
-
Signal
-
-
Right
Lowering
Control voltage
(24 V, STS)
Reverse
Special 1 (F1/F2)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc-com 10Dc-com 2Dc-com 5

Table of Contents