1.
Disconnect the chain hoist from the power supply (mains connection switch) and secure it against switching
on again.
Open and disconnect the service cover.
2.
Remove and open bag (1) with the control cable.
3.
Take the control cable out of the bag.
4.
Turn and disconnect bayonet lock (2) and remove the control cable plug connector.
5.
Unscrew electric equipment cover.
6.
Loosen screw (3) on the control cable locking mechanism and remove the locking mechanism. Remove the
control cable.
Install the new control cable in reverse order.
It must be ensured that
● the groove on the connector holder lines up with the swivel lock in the electric enclosure and
● that the two pins on the enclosure line up with the bayonet lock.
Assemble the control pendant  "Connecting the control pendant", Page 35.
Adjust the height of the control pendant  "Control pendant height adjustment", Page 37.
Tightening torques [Nm]
Electric equipment cover
Service cover
Control cable locking mechanism
Tab. 67
DC-Com 1
DC-Com 2
DC-Com 5
9,5
5,5
11,0
DC-Com 10
7,5
95

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc-com 10Dc-com 2Dc-com 5

Table of Contents