5.10.4

Starting parameter programming mode

Fig. 27
1st step:
Actuate emergency stop.
7-segment display: 8.
Tab. 33
Fig. 28
4th step:
"P." disappears after approx. 2 seconds. Press
the "Lifting" button again and hold it down until
"o." (for O.K.) is displayed.
7-segment display: o.
Tab. 34
50
2nd step:
Press and hold down the "Lifting" button and
unlock emergency stop. Wait for approx. 10
seconds.
7-segment display: (displays a dot)
5th step:
Release the button. Parameter programming
mode is now active.
When parameter programming mode has been
activated, figures "0." to "9." are each succes‐
sively displayed for 2 seconds.
7-segment display: 0. → 1. ··· 9.
3rd step:
When "P." is displayed, release the "Lifting"
button.
7-segment display: P.
6th step:
Press the "Lowering" button to scroll through
the menu items faster.
Each figure represents a parameter, see
 "Meaning of the parameters", Page 49.
7-segment display: