System Operation:

1. Energize System
a. Place Primary Blower Circuit
Breaker in the 'on' position.
b. Place Agitator Circuit Breaker in the
'on' position.
c. For those having the hP3 system: If
you desire to use the auxiliary
blower, place Aux Blower Circuit
Breaker in the 'on' position. If you
do not desire to use the Auxiliary
Blower, place the Aux Blower
Circuit Breaker in the 'off' position.
d. Pull Emergency Stop out. Ready
Light will glow white indicating
system is ready for operation.
2. Activate System from either Electrical
Panel or Wireless Transmitter
a. Press Start Blower button.
Blower(s) that are energized will
start. If you desire to run the
Primary Blower only, then place the
Auxiliary Blower Cicuit Breaker in
"off" position.
b. Press Start Agitator button. The
blower has to be running for 3-4
seconds for the agitator to be able
to start.
i. Note: The agitator will not
start if the blower is not on.
ii. Note: The agitator has a
delay of 3-5 seconds after BLOWER has been started.
iii. Note: Pressing the Stop Agitator button will stop the agitator only.
iv. Note: Pressing the Stop Blower button will shut the entire system
since the agitator can only run when the blower is on.
3. Variable Speed Selection: The Variable Speed switch is a three position switch:
'on', neutral, and 'off'. The Variable Speed can be used to vary the speed of the
Primary Blower. The Variable Speed does not control the Auxiliary Blower; the
Auxiliary Blower is either full on, or off. To use the Variable Speed:
a. Place the Variable Speed switch in the 'on' position.
netzerotools.com
netzerotools.com
TURBO FORCE Instruction Manual
Electrical Panel
|
8
Wireless
Transmitter