RIDE model ice machine start up procedure

The start-up procedure below is intended to ensure that ice machine is operating properly after installation has
been made. Check each item listed and call factory immediately for assistance if you experience problems with
unit.
§ Ice machine MUST be sanitized prior to operation!
§ Consult Operation and Service Manual provided with ice machine for sanitizing instructions.
9.1

Before turning on power

1. Sanitize ice bin.
2. Turn on water to ice machine and check for leaks.
9.2

After turning on power

1. Turn on power switch and immediately press Clean switch to sanitize ice machine. At beginning of
sanitizing process, ice machine will purge all water. Check internal and external drain connections for
leaks.
2. After sanitizing process, ice machine will start. Confirm that gearmotor, fan motor and compressor start
immediately.
3. Check that ice begins to enter dispenser bin area within approximately 10 minutes.