Chapter 2. Installing options

This chapter provides detailed instructions for adding hardware options to your
server. Some option-removal instructions are provided in case you need to remove
one option to install another.

Installation guidelines

Before you begin installing options in your server, read the following information:
v Review the safety information beginning on page v and the guidelines in
v When you need to access the inside of the server to install options, you might
v Make sure that you have an adequate number of properly grounded electrical
v Back up all important data before you make changes to disk drives.
v Have a small flat-blade screwdriver available.
v You do not need to turn off the server to install or replace hot-swap power
v The blue color on components and labels identifies touch points, where you can
v For a list of supported options for your server, go to

System reliability considerations

To help ensure proper system cooling and system reliability, make sure that:
v Each of the drive bays has a drive or a filler panel and electromagnetic
v If the server has redundant power, each of the power-supply bays has a power
v There is adequate space around the server to allow the server cooling system to
v You have followed the cabling instructions that come with optional adapters.
v You have replaced a failed fan as soon as possible.
v You replace a hot-swap drive within 2 minutes of its removal.
v You do not remove the air baffle when the server is operational. Operating the
v Microprocessor socket 2 always contains either a microprocessor baffle or a
© Copyright IBM Corp. 2003
"Handling static-sensitive devices" on page 8. These guidelines will help you work
safely with your server and options.
find it easier to lay the server on its side.
outlets for your server, monitor, and other devices that you will connect to the
server.
supplies, hot-swap drives, or hot-plug Universal Serial Bus (USB) devices.
grip a component, move a latch, and so on.
http://www.ibm.com/pc/us/compat/ on the World Wide Web.
compatibility (EMC) shield installed.
supply installed in it.
work properly. Leave approximately 50 mm (2 in.) of open space around the front
and rear of the server. Do not place objects in front of the fans. For proper
cooling and airflow, replace the server cover before turning on the server.
Operating the server for extended periods of time (over 30 minutes) with the
server cover removed might damage server components.
When installing the server in a rack, make sure that space is available around
the server to enable the server cooling system to work properly. See the
documentation that comes with the rack for additional information.
server without the air baffle might cause the microprocessor to overheat.
microprocessor and heat sink.