Filling Methods

1. Supply (SCUBA) cylinder with SCUBA fill adapter (PN 108325).
2. Compressor with compressor fill adapter (PN M100656).
3. Compressor with HP fill adapter (PN 102865).

Filling with a SCUBA Fill Adapter

NOTE: The EBIS system does not include a SCUBA fill adapter. This adapter
(PN 108325) may be purchased separately (Fig. 6).
CAUTION:
unless you have received the necessary training and authorization to
do so. If done incorrectly, this procedure poses certain hazards which
may cause severe injury or death.
CAUTION:
system gauge to indicate accurate cylinder pressure.
WARNING:
from an air supply where the regulated pressure exceeds 3000 PSI (207
BAR). Doing so could cause a dangerous malfunction to the fill adapter or
weaken the cylinder and safety plug, resulting in serious injury or death.
Do not attempt to fill the EBIS directly from a supply cylinder
The dial pressure gauge is for reference only. Use the fill
DO NOT attempt to use the SCUBA fill adapter to fill the EBIS
Figure 6
O-Ring
9