WARNING:
DO NOT apply any type of petroleum-based lubricant, such
as household oil or motor oil to any part of the EBIS. The EBIS does
not require any lubrication under normal circumstances, except during
annual service performed by a factory trained service technician.
WARNING:
It is important to ensure that the EBIS is always pressurized
whenever it is submerged in order to prevent the entrance of water into
the system. If the system has been completely emptied of air underwater,
it is important to return the EBIS as soon as possible to a factory trained
service technician for visual inspection and any necessary service before
attempting to refill it.
WARNING:
It is important to fill the EBIS only with dry, filtered air with a
water vapor content that does not exceed -65°F / -53ºC dew point. Excess
water vapor in the air can cause ice to form inside the EBIS and interfere
with the operation of the system at colder temperatures.
NOTE: When instructed to remove, unscrew or loosen a part, turn the part
counter-clockwise.
When instructed to install, screw, or tighten a part, turn the part clockwise.
NOTE: When instructed to "OPEN" the handwheel, turn the handwheel
counter-clockwise. The red indicator ring will not be visible in the
handwheel window, this indicates the system in the "ON" position.
When instructed to "CLOSE" the handwheel, turn the handwheel clockwise.
The red indicator ring will be visible in the handwheel window, this indicates
the system is in the"OFF" position.
NOTE: When instructed to depressurize the system, close the handwheel and
depress the second stage purge button for 5 seconds and release for 5 seconds.
Repeat this procedure until the system is depressurized.
NOTE: When instructed to disconnect or reconnect the inflator hose to the
QD fitting, ensure the system is off and depressurized.
Disconnect: Depress the quick disconnect (QD) button on the QD fitting to
remove the inflator hose.
Reconnect: Insert the inflator hose into the QD fitting, making sure the quick
disconnect (QD) button "Pops Up". Ensure the inflator hose is firmly attached
prior to pressurizing the system.