Kai
March 9, 2025
开机显示错误高度,无法进入操作界面
1 comments:
Mr. Anderson
March 9, 2025
The Aqua Lung i770R may display an error related to altitude and restrict access to the operating interface if the altitude level exceeds the device's tested or supported limits. The i770R has altitude settings that adjust for changes in atmospheric pressure, and operating beyond these limits may prevent proper function. Additionally, if the altitude settings are not correctly configured, the dive computer may enter a restricted mode to prevent inaccurate calculations that could compromise diver safety.
The program within the i770R simulates the absorption of inert gases into the body by using a mathematical model. This model is merely a way to apply a limited set of data to a large range of experiences. The i770R dive computer model is based upon the latest research and experiments in decompression theory.
This is an important reason for not pushing the tables, oxygen exposure limits, or entering decompression without proper training. If you dive in situations where your trip would be ruined or your safety would be jeopardized by losing the use of your i770R, a backup instrument system is highly recommended.
Page 4
• If you exceed certain limits, the i770R will not be able to help you get safely back to the surface. These situations exceed tested limits and can result in loss of some functions for 24 hours after the dive in which a violation occurred.
LOW BATTERY DURING A DIVE LOW TMT (TRANSMITTER) BATTERY GAUGE MODE AUDIBLE ALARM ON THE SURFACE BEFORE A DIVE PROXIMITY OF THE TRANSMITTERS AND i770R 34 GAUGE SURF MAIN MENU INITIATING A DIVE DIVE SURFACE MODE GAUGE DIVE MAIN ON THE SURFACE BEFORE A DIVE...
Dive, Gauge, and Free Mode. Though the i770R is easy to use, you will get the most out of your new i770R if you take some time to familiarize yourself with its displays and operation.
GETTING STARTED ACTIVATION To activate the i770R, press and release any button. The i770R will also turn on if its metal contacts become wet and you descend below 1.5 m (5 ft) for 5 seconds. • Upon activation, the unit will display the Activation screen and perform a diagnostic check. The i770R checks the display and voltage at this time to ensure that everything is within tolerance.
They are also used to enter settings and acknowledge the audible alarm. Pressing different combinations of these buttons will navigate through different menus and options of the i770R. The symbols in the table below will illustrate how to proceed through the menus.
This is a base menu that provides access to general items common to all the operating dive modes. When the i770R is activated manually, this is the first screen you will see after the Activation screen. When ready to dive, select Dive, Gauge, or Free Mode from the Mode Submenu.
HOME MENU DC (DIVE COMPUTER) INFO Information displayed on the DC Info screen should be recorded and kept with your sales receipt. It will be required in the event that your i770R requires factory service. exit INFORMATION MODEL i770R SERIAL...
HOME MENU B. Auto Dim While underwater the i770R screen dims after a set time interval from the last button press. This is done to reduce distractions during the dive and to conserve power. The i770R allows you to customize the time interval and degree of dimming. This feature may also be turned off.
Sleep Mode (screen is turned off) or a dive is started. The i770R returns to "sniffing" mode when the i770R returns to Surface Mode after a dive or a button is pushed to wake the com- puter from Sleep Mode on the surface. You will notice the Bluetooth® icon flashing as the Bluetooth®...
As you ascend, the N2 Bar Graph will recede as control shifts to slower compartments. This is a feature of the decompression model that is the basis for multilevel diving, one of the most important advantages that Aqua Lung dive computers offer.
DEEP STOP When the Deep Stop selection is set ON, it will trigger after descending deeper than 24 m (80 ft). The i770R then calculates (continually updating) a Stop Depth equal to ½ the Max Depth.
• The graphics WARNING LOW BATT with a yellow background at the bottom of the screen will flash while in Surface Mode. • The i770R functions continue but screen brightness is limited to 60% of max. WARNING: Recharge the battery before diving if your i770R indicates the Battery Low Warning or Alarm. 00:26...
• The graphics ALARM LOW BATT with a red background at the bottom of the screen while in Surface Mode. • The i770R functions continue until the battery is exhausted but screen brightness is limited to 30% max and dives are not permitted.
• The graphic TMT LOW BATT is displayed on a yellow background at the bottom of the screen. • Transmitter operation continues. WARNING: Change the transmitter battery before starting a new dive or making subsequent dives if your i770R indicates the Transmitter Battery Low Warning. NO-DECO DIVE-T...
The i770R cannot effectively receive a signal when it is held out to the sides of the TMT or held at distances greater than 0.91 m (3 ft) in front of the TMT. Best reception is achieved when the i770R is within less than 0.91 m (3 ft) of the TMT.
DIVE SURFACE MODE TRANSMITTERS The i770R can use up to 4 transmitters to monitor gas supplies. The TMT Menu allows for the programming of the wrist unit to receive the signals from selected Aqua Lung transmitters. See the Dive Mode Features section (p.
DIVE SURFACE MODE 3. SAMPLE RATE The Sample Rate controls how frequently the i770R stores a data snapshot for Diverlog + Down- load during a dive. Setting options are 2, 15, 30, or 60 second intervals. Shorter intervals will provide a more precise record of your dives.
AIR with no PO alarm value for Gas 1, and OFF for Gas 2, 3, and 4. If you save a nitrox mix value for any gas, the i770R will highlight the PO alarm value allowing it to be set. Additionally, the i770R allows for each gas (1 - 4) to have individual PO alarm settings.
DIVE OPERATION INITIATING A DIVE With the i770R in Dive Mode, a dive will commence upon descending to 1.5 m (5 ft) for at least 5 seconds. Below is a diagram to help you navigate Dive Mode functions. to acknowledge...
(Down) button during a dive you can manually record a data snapshot which can later be ac- cessed using the i770R's download feature. The message "EARMARK APPLIED" will be displayed for 3 seconds as confirmation after an earmark is made.
Aqua Lung advises that you should not use an i770R. • If you exceed certain limits, the i770R will not be able to help you get safely back to the surface. These situations exceed tested limits and can result in loss of some functions for 24 hours after the dive in which a violation occurred.
If the transmitter is not reporting, a message will be displayed for 10 seconds before switching gas. Afterwards, the i770R will calculate for the gas change but the Dive Main screen will show a lost transmitter signal. GAS SWITCH...
The stop time will be displayed and count down to 0:00 as long as you stay within 3 m (10 ft) above or below the stop. See Deep Stop in the Dive Features chapter for further details. NOTE: The i770R does not penalize for a missed Deep Stop. DEEP STOP...
Upon ascending to 0.9 m (3 ft) the i770R transitions to Dive Surface Mode. NOTE: The i770R requires a 10 minute surface interval to record a subsequent dive as a separate dive in the Log. Otherwise, the dives will be combined and recorded as a single dive in the i770R memory. DIVE MAIN (<10 min after a dive)
If multiple gasses are set on and the current gas is not the best gas when approaching the decompression stop zone, the i770R will warn you to switch gases. You must confirm the gas switch by pressing the (Select) button.
CV with penalty time still being added. Again, the audible alarm will sound and the DOWN TO STOP message will flash until the audible alarm is silenced *The difference from Conditional Violation is that the i770R will now enter Violation Gauge Mode 5 minutes after surfacing regardless of clear- ing the decompression stops before surfacing.
DTR (NO-DECO or O2 TIME) time will continue to display until the i770R's calculation range is exceeded. * The maximum functional depth (Dive/Gauge/Free = 100 m / 330 ft) is the depth at which the i770R can properly perform all functions.
INITIATING A DIVE With the i770R in Gauge Mode, a dive will commence upon descending to 1.5 m (5 ft) for longer than 5 seconds. Below is a diagram to help you navigate Gauge Dive Mode functions. The dive will end and revert to Surface Mode upon ascent to 0.9 m (3 ft) of depth for at least 1 second.
The max depth on the Alt screen will also be represented by dashes. * The maximum functional depth (Dive/Gauge/Free = 100 m/330 ft) is the depth at which the i770R can properly perform all functions. Upon ascending above the maximum functional depth, current depth will be restored, however, max depth in the More Data screen will continue to be displayed as dashes for the remainder of that dive.
• The mathematical models currently used in the i770R are based on no decompression/decompression multilevel repetitive dive schedules. • These algorithms do not take into account the physiological changes associated with the high pressures that competitive type free diving can expose a diver to.
FREE MODE FREE SURF MAIN MENU To view and adjust i770R Free Dive settings you must navigate through the Free Main Menu. Enter the menu by pressing the (Down) button. Main Menu screens and options will be discussed in the order they appear in the menu.
INITIATING A DIVE With the i770R in Free Mode, a dive will commence upon descending to 1.5 m (5 ft) for longer than 5 seconds. Below is a diagram to help you navigate Free Dive Mode functions. The dive will end and revert to Surface Mode upon ascent to 0.9 m (3 ft) of depth for at least 1 second.
N2 (NITROGEN) WARNING If the nitrogen increase to the yellow (4th) segment on the N2 Bar Graph the i770R will warn you by flashing the message NITROGEN on a yellow background during the audibvle alarm. When the audible warning is silenced the message NITROGEN on a yellow background will remain solid on the screen.
Gauge, or Free operation Modes by holding the (Select) button for at least 2 seconds. • The i770R reverts back to the previous operation mode after 2 minutes unless the Compass Mode is reset by pressing any of the buttons.
COMPASS MAIN MENU The Main menu allows you to adjust compass accuracy. NOTE: The Main Menu can only be accessed while on the surface. During a dive the i770R will use the last saved settings when accessing the Compass Mode.
The Calibration selection in the Compass Main Menu allows you to initiate a calibration. To calibrate the i770R, select Calibrate from the Compass Main Menu. Then follow the onscreen prompts. Rotate and turn the i770R in as many different directions as possible until the unit beeps.
By holdinging the (Down) button during a dive you can manually record a data snapshot which can later be accessed using the i770R's download feature. The message "EARMARK APPLIED" will be displayed for 3 seconds as confirmation after an earmark is made.
Small scratches will naturally disappear underwater. • Soak and rinse the i770R in fresh water at the end of each day of diving, and check to ensure that the areas around the low pressure (depth) sensor, charging port, water contact, and buttons are free of debris or obstruc- tions.
• No adjustments are made during any time that the water contacts are bridged. When diving in high altitude waters from 916 to 4,270 meters (3,001 to 14,000 feet), the i770R automatically ad- justs to these conditions providing corrected depth, and reduced No Decompression and O2 Times at intervals of 305 meters (1,000 feet).
REFERENCE CHANGING THE STRAPS Your i770R is packaged with two different strap options, nylon strap or bungee adapters. NATO (Nylon) Strap Installation: Step 1.Thread the strap Step 2. Pull the strap Step 3. Thread the strap through the strap pins.
1221 1526 1831 2136 2441 2746 3051 3356 3661 3966 (meters) Times greater than 99 minutes display as 99 on the i770R screen. The above figures in the above chart 1220 1525 1830 2135 2440 2745 3050 3355 3660 3965 4270 are actual no decompression time values the i770R uses for calculations.
• Red (Alarm) - Red Icon on the Surface and Dive Main screens. If during a dive, the message ALARM LOW BAT- TERY with up arrows is displayed. If on the surface, the message ALARM LOW BATT flashes until the unit shuts off. The battery must be recharged before using your i770R. Brightness level will automatically be limited to 30% maximum.
Page 102
• Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician. CAUTION: Changes or modification to this unit not expressly approved by Aqua Lung International could void the user's authority to operate the equipment.
Need help?
Do you have a question about the i770R and is the answer not in the manual?
Questions and answers
开机显示错误高度,无法进入操作界面
The Aqua Lung i770R may display an error related to altitude and restrict access to the operating interface if the altitude level exceeds the device's tested or supported limits. The i770R has altitude settings that adjust for changes in atmospheric pressure, and operating beyond these limits may prevent proper function. Additionally, if the altitude settings are not correctly configured, the dive computer may enter a restricted mode to prevent inaccurate calculations that could compromise diver safety.
This answer is automatically generated