Troubleshooting

Note
The required vacuum may not be generated if there is an insufficient supply of air to the
valve terminal.
Malfunction
Workpiece does not
release from the
suction cup
No display
Incomplete display
Outputs do not
switch according to
settings
Settings cannot be
edited ("Lock" in the
display)
Festo – VABF-S4-1-V2B1...-D2 – 1212a English
Possible cause
A vacuum has built up when lifting
large suction cups quickly
The tubing used between the suction
cup and vacuum module is sized
incorrectly (tubing is too long and/or
internal diameter is too small)
Flow control screw is closed
Supply voltage not applied or no
permitted operating voltage
Electrical connections swapped
(incorrect polarity)
Device defective
Display defective
Short circuit/overload at relevant
output
Device defective
Access protection active
Remedy
– Increase the duration and
intensity of the ejector pulse
– Lift the suction cup slower from
the workpiece
– Actively set the ejector pulse
when lifting the suction cup
Replace the tubing
Tubing requirements
Open the flow control screw
Switch on supply voltage / maintain
permitted operating voltage range
Wire in accordance with the circuit
diagram
Replace the device
Replace the device
Eliminate short circuit/overload
Replace the device
Enter the security code (if the
security code has been lost, reset the
device to the factory settings
section 7.3 )
section 4.2