Download Print this page

Frymaster LOV BIGL30 Series Installation, Operation And Maintenance Manual page 42

Gas fryer
Hide thumbs Also See for LOV BIGL30 Series:

Advertisement

Filter pump won't
start or pump stops
during filtering.
Filter Pump runs, but
oil return is very
slow.
Controller displays
OIL IN DRAIN
PAN / CONFIRM
6.2.4 Error Log Codes (For M3000 Controller Only)
Code
ERROR MESSAGE
E03
ERROR TEMP PROBE FAILURE
E04
HI 2 BAD
E05
HOT HI 1
E06
HEATING FAILURE
E20
INVALID CODE LOCATION
E21
FILTER PAD or PAPER PROCEDURE
ERROR (Change Filter Pad or Paper)
E22
OIL IN PAN ERROR
E25
RECOVERY FAULT
E27
LOW TEMP ALARM
A. Power cord is not plugged in or
circuit breaker is tripped.
B. Pump motor has overheated
causing the thermal overload
switch to trip.
C. Blockage in filter pump.
Improperly installed or prepared
filter pan components or cold oil.
Drain valve open or possibility that
oil is in drain pan.
A. Verify that the power cord is fully plugged in
and the circuit breaker is not tripped.
B. If the motor is too hot to touch for more than
a few seconds, the thermal overload switch
has probably tripped. Allow the motor to
cool at least 45 minutes then press the Pump
Reset Switch (see page 4-4).
C. Call your FAS for assistance.
Remove the oil from the filter pan and replace
the filter pad or paper, ensuring that the filter
screen is in place under the pad or paper.
Verify that O-rings are present and in good
condition on filter pan connection fitting.
Press  (CONFIRM) and follow directions for
FILL VAT FROM DRAIN PAN.
EXPLANATION
Temp probe reading out of range
High limit reading is out of range.
High limit temperature is past more than 410°F
(210°C), or in CE countries, 395°F (202°C)
A component has failed such as controller, interface
board, gas valve, ignition module or open-high limit.
SD card removed during update
25 hour timer has expired or a dirty filter may be
causing an incomplete filtration.
Oil may be present in the filter pan.
Recovery time exceeded maximum time limit.
Recovery time should not exceed 2:25 for gas.
Oil temperature has dropped 15°F (9°C) lower than
setpoint in idle mode or 45°F (25°C) in cook mode.
(This message may appear if a product is dropped
and the start cook button is not pressed
immediately or if too large of cook loads are
dropped or adding cold oil to the fryer.)
6-4

Hide quick links:

Advertisement

loading