Download Print this page

Frymaster LOV BIGL30 Series Installation, Operation And Maintenance Manual page 19

Gas fryer
Hide thumbs Also See for LOV BIGL30 Series:

Advertisement

5. Check the programmed temperature thermostat setting. (Refer to the controller manual shipped
with the fryer for the setpoint programming instructions for your particular controller.)
2.5
Converting to another Gas Type
This appliance was configured at the factory for a specific type of gas. Converting from
one type of gas to another requires the installation of specific gas-conversion compo-
nents. Conversion instructions are included with conversion kits.
Switching to a different type of gas without installing the proper conversion
components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A
GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be performed
by qualified, licensed, and authorized installation or service personnel, as defined in
Section 1.7 of this manual.
MANUAL LOV™ Series gas fryers manufactured for non-CE countries use different burners for each
type gas. The burners in fryers built for Propane gas have a special gray-colored coating on the burner
tiles to enable them to withstand the higher caloric value of the Propane gas. Burners designed for use in
propane units may be used in natural gas applications, but not vice versa.
Natural Gas to Propane (LP) Gas
Full Vat before 09/10: PN 826-2527
Dual Vat before 09/10: PN 826-2529
Full Vat after 09/10: PN 826-2965
Dual Vat after 09/10: PN 826-2966
Natural Gas to Propane (LP) Gas
Full Vat before 09/10: PN 826-2745
Dual Vat before 09/10: PN 826-2746
Full Vat after 09/10: PN 826-2969
Dual Vat after 09/10: PN 826-2970
Units manufactured for export to CE countries are equipped with "universal" burners that may be used
with either Natural (G20, G25) gas or Butane (G30) and Propane (G31) gasses.
CE Gas Conversion Kits for Units with Gas Valve 810-1715
G20 or G25 (Natural) to G30 or G31 Gas:
before 09/10 PN 826-2973
after 09/10 PN 826-2975
DANGER
Non-CE Gas Conversion Kits
Non-CE Gas Conversion Kits for Australia
2-8
Propane (LP) Gas to Natural Gas
Full Vat before 09/10: PN 826-2528
Dual Vat before 09/10: PN 826-2530
Full Vat after 09/10: PN 826-2967
Dual Vat after 09/10: PN 826-2968
Propane (LP) Gas to Natural Gas
Full Vat before 09/10: PN 826-2747
Dual Vat before 09/10: PN 826-2748
Full Vat after 09/10: PN 826-2971
Dual Vat after 09/10: PN 826-2972
G30 or G31 to G20 or G25 (Natural) Gas:
before 09/10 PN 826-2974
after 09/10 PN 826-2976

Hide quick links:

Advertisement

loading