HP XP7 User Manual page 78

Business copy for mainframe systems
Hide thumbs Also See for XP7:
Table of Contents

Advertisement

2.
In the log that is displayed, locate the log or error code you are investigating and the SSB1
and SSB2 codes:
(If you are using RAID Manager or BCM window)
Example log:
It was rejected due to SKEY=0x05, ASC=0x20,SSB=0xB9E1,0xB901 on
Serial#(64015)
SSB1 code: B9E1
SSB2 code: B901
(If you are using RAID Manager or BCM operation log file)
Example error code:
11:06:03-37897-10413- SSB = 0xb9a0,2089
SSB1 code: b9a0
SSB2 code: 2089
3.
Locate the description of the SSB1/SSB2 error code combination in the following RAID Manager
or BCM error code table.
For more information about the errors that are not described in the table, contact HP Technical
Support.
SSB2 code
-
200D
201B
2026
2043
2044
2047
2048
204F
205B
2060
2061
78
Troubleshooting Business Copy Z
Description
An error occurred during a BC Z pair task.
The pair task was rejected because the specified THP or Smart V-VOL is not associated with a pool.
The CG pair-split was rejected because the Cnt Ac-J Z pair is suspended ("Suspend/SUSPER" status),
unpaired, or is not split ("Split/SUSPOP" status). The Cnt Ac-J Z S-VOL was the BC Z P-VOL included
in the CG on which the pair-split is being performed.
The Quick Restore was rejected because the cache mode of the specified P-VOL is different from the
cache mode of the external S-VOL.
The volume you specified as a P-VOL was a volume using two mirrors included in a 3-Cnt Ac-J Z DC
multi-target or cascade configuration. The operation was rejected because the volume was used as
a Cnt Ac-J Z data volume.
The volume you specified as an S-VOL was a volume using two mirrors included in a 3-Cnt Ac-J Z DC
multi-target or cascade configuration. The operation was rejected because the volume was used as
a Cnt Ac-J Z data volume.
The pair task was rejected because the current microcode version does not support the specified P-VOL
capacity.
The pair task was rejected because the current microcode version does not support the specified S-VOL
capacity.
The pair task was rejected because the volume you specified as the S-VOL is the volume for Auto LUN,
and the transfer process could not be interrupted.
Retry the operation after the Auto LUN transfer process has completed.
The pair was not created because the specified MU number is in use.
The volume you specified as a BC Z P-VOL was a volume of a Cnt Ac-J Z pair. The pair task was
rejected because the status of the Cnt Ac-J Z pair is not in the required status.
For more information about the required status for each pair task, see
user tasks" (page
67).
The volume you specified as a BC Z S-VOL was a volume of a Cnt Ac-J Z pair. The pair task was
rejected because the status of the Cnt Ac-J Z pair is not in the required status.
"Pair status and supported pair