HP XP7 User Manual page 83

Business copy for mainframe systems
Hide thumbs Also See for XP7:
Table of Contents

Advertisement

SSB2 code
Description
2352
The pair was not restored because the specified P-VOL and S-VOLs is online to the host.
2353
The pair was not deleted because the specified P-VOL and S-VOLs are in the process of being Quick
Split.
2354
The pairresync RAID Manager command was rejected because the P-VOL and S-VOLs is in the
process of being Steady Split.
2357
The pair creation was rejected because the volume you specified as the S-VOL is the P-VOL of the pair
you are splitting or the P-VOL of the pair you are reverse resynchronizing.
2358
The pairresync RAID Manager command was rejected because the volume you specified as the
S-VOL is the P-VOL of the splitting pair.
235B
The volume you specified as a P-VOL is a Cnt Ac-S Z P-VOL. The reverse resynchronization was rejected
because the Cnt Ac-S Z pair is not suspended ("Suspend/SUSPER" status) or split ("Split/SUSPOP"
status).
235C
The volume you specified as the P-VOL is a Cnt Ac-S Z S-VOL. The reverse resynchronization was
rejected because the Cnt Ac-S Z pair is not suspended ("Suspend/SUSPER" status) or split
("Split/SUSPOP" status).
235D
The volume you specified as an S-VOL was a Cnt Ac-S Z P-VOL. The reverse resynchronization was
rejected because the Cnt Ac-S Z pair is not suspended ("Suspend/SUSPER" status) or split
("Split/SUSPOP" status).
236C
The reverse resynchronization was rejected because the volume you specified as the P-VOL has the
S-VOL Disable attribute assigned by the Data Retention.
236D
The pair task was rejected because the volume you specified as the S-VOL has the S-VOL Disable
attribute assigned by the Data Retention.
2370
The pair task was rejected because the volume you specified as the P-VOL is not mounted.
2371
The pair task was rejected because the volume you specified as the P-VOL is blocked.
2372
The pair task was rejected because the volume you specified as the P-VOL is being formatted or
shredded.
2373
The pair task was rejected because the volume you specified as the P-VOL is a command device.
2380
The pair task was rejected because of one of the following reasons:
The volume you specified as the S-VOL is not mounted.
The MU number is 3 or larger.
2381
The pair task was rejected because the volume you specified as the S-VOL is blocked.
2382
The pair task was rejected because the volume you specified as the S-VOL is being formatted or
shredded.
2383
The pair task was rejected because the volume you specified as the S-VOL is a command device.
2387
The pair was not created because the volume you specified as the P-VOL is the volume for Auto LUN.
2394
The pair was not registered in the CG because the number of the pairs assigned to the CG has
exceeded the defined maximum number of pairs.
2395
The pair task was rejected because you are reverse resynchronizing the pair sharing the specified
volume as the P-VOL.
2396
The pair task was rejected because you are reverse resynchronizing the L1 pair sharing the specified
P-VOL as the root volume.
2397
The pair task was rejected because you are reverse resynchronizing the L2 pair sharing the specified
P-VOL or S-VOL as the node volume.
2398
The reverse resynchronization was rejected because the pair is not split ("Split/SUSPOP" status) or
suspended ("Suspend/SUSPER" status).
Locating and interpreting error codes and logs using the RAID Manager or BCM
83

Advertisement

Table of Contents
loading

Table of Contents