HP StorageWorks
Disk Array XP operating system
configuration guide: IBM AIX
XP12000
XP10000
XP1024
XP128
This guide describes the requirements and procedures for connecting and configuring the XP family of
disk arrays to work with an IBM system running the IBM AIX operating system.
Part number: A5951–96045
Seventh edition: November, 2005

Advertisement

Table of Contents
loading

Summary of Contents for HP XP1024

  • Page 1 Disk Array XP operating system configuration guide: IBM AIX XP12000 XP10000 XP1024 XP128 This guide describes the requirements and procedures for connecting and configuring the XP family of disk arrays to work with an IBM system running the IBM AIX operating system.
  • Page 2 Legal and notice information © Copyright 2003-2005 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license.
  • Page 3: Table Of Contents

    Contents Preface ......About this guide ....... . Intended audience .
  • Page 4 Configure disk array devices ......Changing the device parameters ......Assigning the new devices to volume groups .
  • Page 5: Preface

    Related documentation The following documents provide related information: • HP StorageWorks Disk Array XP128: Owner’s Guide • HP StorageWorks Disk Array XP1024: Owner’s Guide • HP StorageWorks XP10000 Disk Array: Owner’s Guide • HP StorageWorks XP12000 Disk Array: Owner’s Guide You can find these documents on the storage web site:...
  • Page 6: Document Conventions And Symbols

    Document conventions and symbols Convention Element Blue text Cross-reference links and email addresses • Keys that are pressed Bold • Text typed into a GUI element, such as a box • GUI elements that are clicked or selected, such as menu and list items, buttons, tabs, and check boxes •...
  • Page 7: Hp Technical Support

    TIP: Provides helpful hints and shortcuts. HP technical support In North America, call technical support at 1-800-633-3600, available 24 hours a day, 7 days a week. Outside North America, call technical support at the location nearest you. Telephone numbers for worldwide technical support are listed on the HP support web site: http://www.hp.com/support.
  • Page 8 Preface...
  • Page 9: Installation

    XP128: From 8 to 128 drives for up to 36 TB, 48 FC ports XP1024: From 8 to 1024 drives for up to 149 TB, 64 FC ports XP10000: Up to 240 drives for up to 69.2 TB, 48 FC ports XP12000: Up to 1152 drives for up to 332 TB, 128 FC ports •...
  • Page 10: Fibre Channel Interface

    HP StorageWorks Cache LUN XP HP StorageWorks Auto Path XP HP StorageWorks Cluster Extension XP HP StorageWorks Performance Advisor XP Fibre Channel interface The XP family of disk arrays supports these Fibre Channel elements: • Connection speed of 1 Gbps and 2 Gbps •...
  • Page 11: Snmp Configuration

    SNMP configuration The XP family of disk arrays supports standard Simple Network Management Protocol (SNMP) for remotely managing the disk array. The SNMP agent on the service processor (SVP) performs error-reporting operations requested by the SNMP manager. SNMP properties are usually set from the SVP but they can also be set remotely using Remote Web Console XP, Command View XP, or Command View XP Advanced Edition.
  • Page 12: Installation Procedures

    Installation procedures Perform these actions to install and configure the disk array: 1. Install and configure the disk array • Setting the host mode for the disk array ports Setting the System Option Modes • • Configuring the Fibre Channel ports 2.
  • Page 13: Install And Configure The Disk Array

    Install and configure the disk array The HP service representative performs these tasks: • Assembling hardware and installing software • Loading the microcode updates • Installing and formatting devices After these tasks are finished, you will use Remote Web Console, Command View, Command View XP Advanced Edition, or LUN Configuration and Security Manager to complete the remaining tasks listed below.
  • Page 14 For the XP1024/XP128 arrays, the host mode can also be set at the port information window in Command View XP AE. Installation...
  • Page 15: Setting The System Option Modes

    Setting the System Option Modes The HP service representative sets the System Option Mode(s) based on the operating system and software configuration of the host. Description and Usage Mode Level HA Software None Optional ON: Response to the Inquiry command is changed, and the volume can be used from VeritasNetBackUP in heterogeneous OS configuration, such as HP-UX.
  • Page 16: Configuring The Fibre Channel Ports

    Configuring the Fibre Channel ports Configure the disk array Fibre Channel ports by using Remote Web Console (shown), Command View, or Command View XP AE. Select the settings for each port based on your storage area network topology. Use switch zoning if you connect different types of hosts to the array through the same switch.
  • Page 17: Fabric And Connection Parameter Settings

    Fabric and connection parameter settings Set each array port to FABRIC ON or OFF with connections of POINT-TO-POINT or FC-AL as shown in the following figure and table. For detailed topology information, refer to the HP StorageWorks SAN Design Reference Guide on the http://www.hp.com website.
  • Page 18: Install And Configure The Host

    Install and configure the host This section explains how to install and configure the host and host bus adapters (HBAs) that connect the host to the disk array. Loading the OS and software Follow the manufacturer’s instructions to load the operating system and software onto the host.
  • Page 19: To Check The Firmware Level

    To check the firmware level: The HBA should have the proper version of firmware installed. Use the lsdev command to display the device object. Example # lsdev -Cc adapter Use the lscfg command to display the firmware level. Example # lscgfg -vl fcsX fcsX is the fiber device object (typically fcs0).
  • Page 20 You can use the slash (“/”) to search for the components in the list. HBA FC6227 requires these drivers: devices.pci.df1000f7 devices.fcp.disk Press Enter. Wait for status to change from RUNNING to OK. Check installation summary result (SUCCESS). Press F10. Use the smit devinst command to configure the devices. Installation...
  • Page 21: Clustering And Fabric Zoning

    Clustering and fabric zoning If you plan to use clustering, install and configure the clustering software on the servers. Clustering is the organization of multiple servers into groups. Within a cluster, each server is a node. Multiple clusters compose a multi-cluster environment. The following example shows a multi-cluster environment with three clusters, each containing two nodes.
  • Page 22: Fabric Zoning And Lun Security For Multiple Operating Systems

    Fabric zoning and LUN security for multiple operating systems You can connect multiple clusters of various operating systems to the same switch and fabric using appropriate zoning and LUN security as follows: • Storage port zones may overlap if more than one operating system needs to share an array port.
  • Page 23: Defining The Paths

    Defining the paths Use Remote Web Console (shown), Command View, or Command View XP AE to define paths (LUNs) between hosts and volumes in the disk array. This process is also called “LUN mapping.” In Remote Web Console and Command View, LUN mapping includes: •...
  • Page 24: Verifying Host Recognition Of Disk Array Devices

    and their ports, WWNs, nicknames, and LDEVs for later use in verifying host and device configuration. Verifying host recognition of disk array devices To verify that the host recognizes the disk array devices: Log into the host as an administrator (root). If the disk array LUNs are defined after the IBM system is powered on, issue a cfgmgr command to recognize the new devices.
  • Page 25: Configure Disk Array Devices

    Configure disk array devices Disks in the disk array are configured using the same procedure for configuring any new disk on the host. This includes the following procedures: • Changing the device parameters • Assigning the new devices to volume groups •...
  • Page 26 To change the device parameters using the AIX command line: To change the R/W timeout parameter, enter: chdev –1 hdisk –a rw_timeout=’60’ To change the queue depth parameter, enter: chdev –l hdisk –a queue_depth=’ ’ where x is a value from the above table. To change the queue type parameter, enter: chdev –l hdisk –a q_type=’simple’...
  • Page 27 Select Devices. Example System Management Move cursor to desired item and press Enter. Software Installation and Maintenance Software License Management Devices System Storage Management (Physical & Logical Storage) Security & Users Communications Applications and Services Print Spooling Problem Determination Performance & Resource Scheduling System Environments Processes &...
  • Page 28: Assigning The New Devices To Volume Groups

    Repeat these steps for each OPEN-x device on the disk array. Assigning the new devices to volume groups Assign the new devices to volume groups using the AIX system’s Logical Volume Manager (accessed from within SMIT). This operation is not required when the volumes are used as raw devices.
  • Page 29 Select Volume Groups. Example Logical Volume Manager Move cursor to desired item and press Enter. Volume Groups Logical Volumes Physical Volumes Paging Space Select Add a Volume Group. Example Volume Groups Move cursor to desired item and press Enter. List All Volume Groups Add a Volume Group Set Characteristics of a Volume Group List Contents of a Volume Group...
  • Page 30 Enter or select values for the following fields: Volume Group name (the volume group can contain multiple hdisk devices) Physical partition size in megabytes, see Physical partition size table Physical Volume names To enter values, place the cursor in the field and type the value. To select values, place the cursor in the field and press F4.
  • Page 31: Creating The Journaled File Systems

    Creating the Journaled File Systems Create the Journaled File Systems using the System Manager Information Tool (SMIT). This operation is not required when the volumes are used as raw devices. The largest file system permitted in AIX is 64 GB. To create the Journaled File Systems: Start SMIT.
  • Page 32 Select Add / Change / Show / Delete File Systems . Example File Systems Move cursor to desired item and press Enter. List All File Systems List All Mounted File Systems Add / Change / Show / Delete File Systems Mount a File System Mount a Group of File Systems Unmount a File System...
  • Page 33 Select Add a Standard Journaled File System. Example Add a Journaled File System Move cursor to desired item and press Enter. Add a Standard Journaled File System Add a Compressed Journaled File System Add a Large File Enabled Journaled File System Select a volume group, and press Enter.
  • Page 34 Enter values for the following fields: SIZE of file system (in 512-byte blocks). Enter the lsvg command to display the number of free physical partitions and physical partition size. Calculate the maximum size of the file system as follows: (FREE PPs - 1) x (PP SIZE) x 2048 Mount Point: Enter mount point name.
  • Page 35: Mounting And Verifying The File Systems

    Mounting and verifying the file systems Mount the file systems and verify that the file systems were created correctly and are functioning properly. To mount and verify the file systems: Mount the file system. Enter: mount_point_name mount Example # mount /vg01 Repeat step 1 for each new file system.
  • Page 36 Use the df command to verify that the file systems have successfully automounted after a reboot. Any file systems that were not automounted can be set to automount using the SMIT Change a Journaled File System screen. If you are using HACMP or HAGEO, do not set the file systems to automount. Example # df File system 512-blocks...
  • Page 37: Troubleshooting

    2 Troubleshooting This section includes resolutions for various error conditions you may encounter. If you are unable to resolve an error condition, ask your HP support representative for assistance. See Calling the HP support center Error conditions Depending on your system configuration, you may be able to view error messages (R-SIMS) as follows: •...
  • Page 38 Error Condition Recommended Action The logical devices are not Verify that the READY indicator lights on the disk array recognized by the host. are ON. Verify that fiber cables are correctly installed and firmly connected. Verify that the target IDs are properly configured. The LUNs for each TID must start at 0 and continue sequentially without skipping any numbers.
  • Page 39: Calling The Hp Support Center

    Calling the HP support center If you are unable to resolve an error condition, contact the HP support center for assistance. Contact Information In North America, call technical support at 1-800-633-3600, available 24 hours a day, 7 days a week. Outside North America, call technical support at the location nearest you.
  • Page 40 Troubleshooting...
  • Page 41: A Path Worksheet

    A Path Worksheet LDEV (CU:LDEV) (CU = Device SCSI Bus Path 1 Alternate Paths control unit) Type Number 0:00 TID: TID: TID: LUN: LUN: LUN: 0:01 TID: TID: TID: LUN: LUN: LUN: TID: TID: TID: 0:02 LUN: LUN: LUN: TID: TID: TID: 0:03...
  • Page 42 Path Worksheet...
  • Page 43: B Disk Array Supported Emulations

    Supported emulations Emulation XP Model Emulation Supported LUSE LUSE & CVS OPEN-3 OPEN-8 XP128 OPEN-9 XP1024 OPEN-E XP10000 OPEN-K XP12000 OPEN-L OPEN-M OPEN-V Disk Array XP operating system configuration guide: IBM AIX...
  • Page 44: Emulation Specifications

    Emulation specifications Category Sector Sectors Capacity Emulation Blocks (512 # of Heads (Note 2) (Note (Note 1) Size bytes ) Cylinders (bytes) Track OPEN-3 4806720 3338 2347 SCSI disk OPEN-8 14351040 9966 7007 SCSI disk OPEN-9 14423040 10016 7042 SCSI disk OPEN-E 28452960 19759...
  • Page 45 Note 1: The availability of an emulation depends on the disk array. Note 2: The devices are defined to the host as SCSI disk devices, even though the interface is Fibre Channel. Note 3: The device capacity can sometimes be changed by the BIOS or host adapter board. This may make actual capacity different from that listed in the table.
  • Page 46: Disk Parameters By Emulation Type

    Example For an OPEN-V CVS volume with capacity = 49 MB: # of cylinders = ↑49 × 16/15↑ = ↑52.26↑ (rounded up to next integer) = 53 cylinders OPEN-3/8/9/E: The number of cylinders for a CVS LUSE volume = # of cylinders = ↑ (capacity (MB) specified by user) ×...
  • Page 47 Emulation Type Parameter OPEN-3 OPEN-3*n OPEN-3 CVS OPEN-3 CVS*n (n=2 to 36) (n=2 to 36) 6,300 6,300 6,300 6,300 Number of rotations of the disk Set optionally Set optionally Set optionally Set optionally a partition offset (Starting block in a partition) b partition offset (Starting block Set optionally Set optionally...
  • Page 48 Emulation Type Parameter OPEN-3 OPEN-3*n OPEN-3 CVS OPEN-3 CVS*n (n=2 to 36) (n=2 to 36) 8,192 8,192 8,192 8,192 e partition block size 8,192 8,192 8,192 8,192 f partition block size 8,192 8,192 8,192 8,192 g partition block size 8,192 8,192 8,192 8,192...
  • Page 49 OPEN-8 parameters Emulation Type Parameter OPEN-8 OPEN-8*n OPEN-8 CVS OPEN-8 CVS*n (n=2 to 36) (n=2 to 36) Disk category Winchester Winchester Winchester Winchester SCSI SCSI SCSI SCSI Control type Sectors/tracks Tracks/cylinder Set optionally 9,966 9,966*n Number of all cylinders Depends on Depends on configuration of configuration of...
  • Page 50 Emulation Type Parameter OPEN-8 OPEN-8*n OPEN-8 CVS OPEN-8 CVS*n (n=2 to 36) (n=2 to 36) Set optionally Set optionally Set optionally Set optionally f partition size g partition size Set optionally Set optionally Set optionally Set optionally h partition size Set optionally Set optionally Set optionally...
  • Page 51 OPEN-9 parameters Emulation Type Parameter OPEN-9 OPEN-9*n OPEN-9 CVS OPEN-9 CVS*n (n=2 to 36) (n=2 to 36) Disk category Winchester Winchester Winchester Winchester SCSI SCSI SCSI SCSI Control type Sectors/tracks Tracks/cylinder 10,016 10,016*n Number of all cylinders Depends on Depends on configuration of configuration of 6,300...
  • Page 52 Emulation Type Parameter OPEN-9 OPEN-9*n OPEN-9 CVS OPEN-9 CVS*n (n=2 to 36) (n=2 to 36) Set optionally Set optionally Set optionally Set optionally f partition size g partition size Set optionally Set optionally Set optionally Set optionally h partition size Set optionally Set optionally Set optionally...
  • Page 53 OPEN-E parameters Emulation Type Parameter OPEN-E OPEN-E*n OPEN-E CVS OPEN-E CVS*n (n=2 to 36) (n=2 to 36) Disk category Winchester Winchester Winchester Winchester SCSI SCSI SCSI SCSI Control type Sectors/tracks Tracks/cylinder 19,759 19,759*n Number of all cylinders Depends on Depends on configuration of configuration of 6,300...
  • Page 54 Emulation Type Parameter OPEN-E OPEN-E*n OPEN-E CVS OPEN-E CVS*n (n=2 to 36) (n=2 to 36) Set optionally Set optionally Set optionally Set optionally f partition size g partition size Set optionally Set optionally Set optionally Set optionally h partition size Set optionally Set optionally Set optionally...
  • Page 55 Notes for disk parameters The value of pc is calculated as follows: pc = nc The nc of OPEN-x CVS corresponds to the capacity specified by SVP or remote console. The CVS size of OPEN-x is specified by capacity (megabyte), not by number of cylinders.
  • Page 56: Byte Information Table

    Byte information table Values in this table assume that large files are stored in large volumes, and the maximum number of files stored in each device type is approximately the same for each device type. Byte information table Category LU Product Name Number of Bytes per Inode OPEN-3...
  • Page 57: Physical Partition Size Table

    Physical partition size table Category LU Product Name Physical Partition Size in Megabytes OPEN-3 OPEN-3 OPEN-3*2 to OPEN-3*3 OPEN-3*4 to OPEN-3*6 OPEN-3*7 to OPEN-3*13 OPEN-3*14 to OPEN-3*27 OPEN-3*28 to OPEN-3*36 OPEN-8 OPEN-8 OPEN-8*2 OPEN-8*3 to OPEN-8*4 OPEN-8*5 to OPEN-8*9 OPEN-8*10 to OPEN-8*18 OPEN-8*19 to OPEN-8*36 OPEN-9 OPEN-9...
  • Page 58 Category LU Product Name Physical Partition Size in Megabytes OPEN-x*n CVS 35 to1800 1801 to 2300 2301 to 7000 7001 to 16200 13201 to 32400 32401 to 64800 64801 to 126000 126001 to 259200 259201 - 518400 518401 and higher 1024 Disk array supported emulations...
  • Page 59: Glossary

    Glossary Arbitrated loop. AL-PA Arbitrated loop physical address. array group A group of 4 or 8 physical hard disk drives (HDDs) installed in an XP disk array and assigned a common RAID level. RAID1 array groups consist of 4 (2D+2D) or 8 HDDs (4D+4D). RAID5 array groups include a parity disk but also consist of 4 (3D+1P) or 8 HDDs (7D+1P).
  • Page 60 DKU (disk cabinet The array cabinets that house the disk array physical disks. unit) emulation modes The logical devices (LDEVs) associated with each RAID group are assigned an emulation mode that makes them operate like OPEN system disk drives. The emulation mode determines the size of an LDEV: OPEN-3: 2.46 GB OPEN-8: 7.38 GB...
  • Page 61 Open Fibre Control. OPEN- A general term describing any one of the supported OPEN emulation modes (for example, OPEN-L). Operating system. Physical address. path “Path” and “LUN” are synonymous. Paths are created by associating a port, a target, and a LUN ID with one or more LDEVs.
  • Page 62 volumes; one is identified as CU = 00 and LDEV = 00, and the other as CU = 01 and LDEV = 00; they are two unique separate virtual storage devices within the XP array. Volume size customization. Synonymous with CVS. World Wide Name.
  • Page 63: Index

    Index device(s) arbitrated-loop physical address, 16 configuration, 25 audience, 5 emulation types, 10 Auto LUN XP, 9 logical volume, 28 Auto Path XP, 10 logical, not recognized by host, 38 parameters change using SMIT command line, 26 changing, 25 Business Copy XP, 9, 11 changing using AIX command line, 26...
  • Page 64 fabric environment installation, 9 parameter settings, 17 connecting disk array, 22 port addresses, 16 overview, 12 zoning, 21, 22 interface, Fibre Channel, 10 failover, 10 features, disk array, 9 Fibre Channel connection speed, 10 Journaled File Systems, creating, 31 interface, 10 parameter settings, 17 ports,...
  • Page 65 physical volumes, cannot be created, HP, 7 text symbols, 6 port(s) topology, fabric, 17 address, 16 troubleshooting, 37 Fibre Channel, 16 error conditions, 37 technical support, 39 R-SIMS, 37 RAID Manager command devices, 11 volume(s) RAID Manager XP, 9 groups, assigning new device, 28 related documentation, 5...

This manual is also suitable for:

Xp12000Xp10000Xp128