Omron SYSMAC CV Series Operation Manual page 65

Host link system, unit
Hide thumbs Also See for SYSMAC CV Series:
Table of Contents

Advertisement

Sending Commands to Host Computers
RECV(193) Instruction
@
x
x
Node No.
Header code
x
x
x
DA2
SNA
x
x
FCS
9. Response monitor time: Set the response monitor time if the response des-
ignation is set to OFF.
The setting range of each control data item is as follows:
Item
No. of words transferred
Host Link Unit
communications port no.
Destination network
address
Destination node number
Destination unit address
Response response
Communications port no.
No. of retries
Response monitor time
Note In order to execute the SEND(192) instruction properly, it is necessary to pre-
pare a program on the host computer so that the host computer will process the
data that the host computer has received.
The RECV(193) instruction enables data from the host computer to be written to
the memory areas of the local PC.
When the RECV(193) instruction is executed, the CV-mode command
"MEMORY AREA READ" (command code 0101) will be sent to the host comput-
er in the following command block format.
O
F
0
8
x
ICF
Response delay
x
x
x
x
x
SA1
SA2
*
r
Terminator
0001 to 0100 (1 to 256 words)
00 or 01: Communications port 1
02:
Communications port 2
00:
Local network
01 to 7F: Network address (1 to 127)
00:
Within local PC
01 to 7E: Node number (1 to 126) (SYSMAC NET)
01 to 3E: Node number (1 to 62) (SYSMAC LINK)
10 to 1F: Host Link Unit (unit numbers 1 to 15)
0 (OFF): Response required
1 (ON):
No response required
0 to 7 (0 to 7)
0 to F (0 to 15)
0000:
Default (2 s)
0001 to FFFF (0.1 to 6,553.5 s with 0.1-s increments)
0
x
0
x
x
RSV
GCNT
DNA
x
x
0
1
0
SID
Command code
Section 4-4
Range
x
x
x
DA1
1
Data
(1,080 characters max.)
61