For detailed information about setting up the Ethernet
switch, refer to the documentation supplied with the
Ethernet switch.
e REMOTE connector (BNC type)
Connect this connector with a BNC cable to an S-BUS data
link via a T bridge.
An S-BUS data link is a single signaling circuit (S-BUS)
to which multiple devices can be connected to exchange
data.
Connecting devices such as HDS-X series routing
switchers and remote panels to an S-BUS data link enables
the following kinds of control.
• Returning to the S-BUS, tally data created by this unit on
the basis of data received from other devices
• Switching the cross-points of a routing switcher from the
center control panel
• Switching the cross-points of a switcher from the remote
panel
• Displaying on the center control panel source names set
on a routing switcher
f LTC IN (longitudinal time code input) connector
(BNC type)
Connect to a time code generator.
g REF IN (reference signal input) connector
(BNC type)
If you wish to synchronize this unit to an external reference
signal, input the reference signal. For an HDTV system,
input an HD tri-level sync signal, black burst signal, or
analog sync signal. For an SDTV system, input a black
burst signal or analog sync signal.
The two connectors have a loop-through configuration.
Signal input to one connector can be output from the other
connector. If you will not be using the loop-through
output, be sure to terminate the unused connector with the
supplied 75Ω terminator.
h 75Ω ON/OFF switch
This is a 75-ohm termination switch for reference video
signal input.
i EDITOR PANEL connector (D-sub 15-pin,
RS-422A)
It will be used for connecting an optional editing keyboard.
j EXT (extension) PANEL connector (D-sub 50-pin,
special interface)
Connect to the MKS-8075 Extension Adaptors to install
operation modules apart.
k MENU PANEL connector (D-sub 50-pin,
special interface)
Connect to the menu panel.
10
Location and Function of Parts
l DATA connector (RJ-45)
Connect to an Ethernet switch.
The MVS-8000A/DVS-9000 Switcher Processor Pack, the
MVE-8000A DME Processor Pack and other devices can
be connected in the same way to the Ethernet switch to
form a network for exchange of signals between the
devices. This network is used primarily for exchange of
various types of data (key frame effects, snapshots, etc.)
and still pictures of frame memory.
m EXT (extension) DISPLAY connector
(high-density D-sub 15-pin, analog RGB)
Connect to an XGA (Extended Graphics Array) monitor.
n U (signal ground) terminal
Connect to the system ground.
Caution
For safety, do not connect the connector for peripheral
device wiring that might have excessive voltage to the
following ports.
• PERIPH connector
• DATA connector
• CTRL connector
Follow the instructions for the above ports.