Flow Of System Diagnostics; Starting System Diagnostics - NEC Express5800 Maintenance Manual

Hide thumbs Also See for Express5800:
Table of Contents

Advertisement

Chapter 1 Maintenance
8.2

Flow of System Diagnostics

8.2.1 Starting System Diagnostics

Run System Diagnostics in the following procedure.
1. Insert TeDoLi media (system diagnostic tool) provided with the server into CD/DVD drive of the server
or CD/DVD drive connected to the server via remote media feature and reboot the system.
2. To boot from TeDoLi media, enter BIOS SETUP and select DVD form BOOT Option#1 in the BOOT
menu. Then select Save & Exit menu, system is rebooted.
If the "Maintenance Mode" is set to "Enable", the following screen is displayed. Select a
drive where TeDoLi media is inserted.
3. When the system starts, enter the boot option. Specify the console used for system diagnostics after
"ELILO boot:". When the system starts without entering the boot option, system diagnostics is
performed on SOL screen.
ELILO boot: ..
Console used for system diagnostics
SOL
Serial
VGA
Express5800/A1040b, A2040b, A2020b, A2010b Maintenance Guide
54
Note
Restore previous boot option after system diagnostics completed.
[option]
<ENTER>
Boot option
Not specified
tedoli
tedoli_vga