Fluke MicroMapper Pro Instruction Sheet page 19

Vdv cable tester
Table of Contents

Advertisement

Split pairs
Coaxial
termination
measurements
Toner
Calibration
cycle
Display
Input
protection
Battery type
and life
Auto shutoff
Dimensions and
weight
Certifications
and compliance
Section with split pair must be at least 3 m long and greater than
10% of the cable length.
Loop resistance between 5 Ω and 350 Ω is considered a
termination resistance. Loop resistance below 5 Ω is considered a
short. Loop resistance greater than 350 Ω is not displayed. Typical
accuracy: 5% ±1 Ω
Generates four tones compatible with most analog probes. Tones
are generated on all wire pairs and the coaxial connector.
Factory calibration not required
LCD, fixed-segment, 2.19 in x 1.69 in (5.6 cm x 4.2 cm)
50 V dc
Tester: 6 AAA alkaline batteries, 100 hours continuous use (non-
toner modes), low battery indicator (
PRO3000 probe: 9 V alkaline
5 minutes with no key presses.
In toner mode, turns off after 1 hour.
Tester: 5.9 in x 2.8 in x 1.4 in (152 mm x 72 mm x 35 mm), 8.8 oz
(250 g)
Remote ID: 2.4 in x 0.9 in x 0.9 in (60 mm x 23 mm x 22 mm),
1.1 oz (30 g)
P
3000 probe: 9.8 in x 1.6 in x 1.3 in (24.9 cm x 4.1 cm x 3.3 cm)
RO
EN 61326-1, EN 61010
P
Conforms to relevant European Union directives.
;
Conforms to relevant Australian standards.
) on display